Kachooei Amir Reza, Rivlin Michael, Wu Fei, Faghfouri Aram, Eberlin Kyle R, Ring David
Аннотация
PURPOSE: To study the intraobserver and interobserver reliability of the diagnosis of interosseous ligament (IOL) rupture in a cadaver model.
METHODS: On 12 fresh frozen cadavers, radial heads were cut using an identical incision and osteotomy. After randomization, the soft tissues of the limbs were divided into 4 groups: both IOL and triangular fibrocartilage (TFCC) intact; IOL disruption but TFCC intact; both IOL and TFCC divided; and IOL intact but TFCC divided. All incisions had identical suturing. After standard instruction and demonstration of radius pull-push and radius lateral pull tests, 10 physician evaluators with different levels of experience examined the cadaver limbs in a standardized way (elbow at 90° with the forearm held in both supination and pronation) and were asked to classify them into one of the 4 groups. Next, the same examiners were asked to re-examine the limbs after randomly changing the order of examination.
RESULTS: The interobserver reliability of agreement for the diagnosis of IOL injury (groups 2 and 3) was fair in both rounds of examination and the intraobserver reliability was moderate. The intra- and interobserver reliabilities of agreement for the 4 groups of injuries among the examiners were fair in both rounds of examination. The sensitivity, specificity, accuracy, positive, and negative predictive values were all around 70%. The likelihood of a positive test corresponding with the presence of IOL rupture (positive likelihood ratio) was 2.2. The likelihood of a negative test correctly diagnosing an intact IOL was 0.40.
CONCLUSIONS: In cadavers, intraoperative tests had fair reliability and 70% accuracy for the diagnosis of IOL rupture using the push-pull and lateral pull maneuvers. The level of experience did not have any effect on the correct diagnosis of intact versus disrupted IOL.
CLINICAL RELEVANCE: Although not common, some failure of surgeries for traumatic elbow fracture-dislocations is because of failure in timely diagnosis of IOL disruption.
METHODS: On 12 fresh frozen cadavers, radial heads were cut using an identical incision and osteotomy. After randomization, the soft tissues of the limbs were divided into 4 groups: both IOL and triangular fibrocartilage (TFCC) intact; IOL disruption but TFCC intact; both IOL and TFCC divided; and IOL intact but TFCC divided. All incisions had identical suturing. After standard instruction and demonstration of radius pull-push and radius lateral pull tests, 10 physician evaluators with different levels of experience examined the cadaver limbs in a standardized way (elbow at 90° with the forearm held in both supination and pronation) and were asked to classify them into one of the 4 groups. Next, the same examiners were asked to re-examine the limbs after randomly changing the order of examination.
RESULTS: The interobserver reliability of agreement for the diagnosis of IOL injury (groups 2 and 3) was fair in both rounds of examination and the intraobserver reliability was moderate. The intra- and interobserver reliabilities of agreement for the 4 groups of injuries among the examiners were fair in both rounds of examination. The sensitivity, specificity, accuracy, positive, and negative predictive values were all around 70%. The likelihood of a positive test corresponding with the presence of IOL rupture (positive likelihood ratio) was 2.2. The likelihood of a negative test correctly diagnosing an intact IOL was 0.40.
CONCLUSIONS: In cadavers, intraoperative tests had fair reliability and 70% accuracy for the diagnosis of IOL rupture using the push-pull and lateral pull maneuvers. The level of experience did not have any effect on the correct diagnosis of intact versus disrupted IOL.
CLINICAL RELEVANCE: Although not common, some failure of surgeries for traumatic elbow fracture-dislocations is because of failure in timely diagnosis of IOL disruption.