Transplantation proceedings · 2016
Prediction of Complement-Binding Capacity of HLA Antibodies Based on Mean Fluorescence Intensity.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhao J, Fu Y X, Yang T, Shen Z Y, Wu C L
Аннотация
BACKGROUND: Human leukocyte antigen (HLA) antibodies estimated by Luminex single-antigen beads, especially those that fix complement, are associated with antibody-mediated rejection and graft failure. However, the relationship between HLA antibody strength and complement-binding ability is controversial.
METHODS: Serum samples of 31 sensitized renal patients waiting for renal transplantation were retrospectively analyzed by IgG-Luminex to identify HLA antibodies and in parallel by C1q-Luminex to determine the complement binding of HLA antibodies.
RESULTS: The percentage of HLA class I antibodies binding with C1q was lower than that of HLA class II antibodies (43.2% vs. 51.3%, P = .006). The mean fluorescence intensities (MFI) of IgG-Luminex correlated with the MFI of C1q-Luminex for the same antibodies (Spearman correlation; class I, r = 0.665, P < .01; class II, r = 0.761, P < .01). Receiver operating characteristic (ROC) curve analysis showed that the MFIs of HLA antibodies by IgG-Luminex predicted their C1q-binding abilities (area under the curve [AUC] class I = 0.917; AUC class II = 0.927). Using MFI cutoff values of 8238 and 6754 in IgG-Luminex for HLA class I and class II antibodies, respectively, the sensitivity and specificity for C1q binding were 82.4% and 87.4% for class I antibodies and 90.9% and 82% for class II antibodies.
CONCLUSIONS: The MFI of HLA antibodies by IgG-Luminex predicts the complement-binding capability to a certain extent before transplantation.
METHODS: Serum samples of 31 sensitized renal patients waiting for renal transplantation were retrospectively analyzed by IgG-Luminex to identify HLA antibodies and in parallel by C1q-Luminex to determine the complement binding of HLA antibodies.
RESULTS: The percentage of HLA class I antibodies binding with C1q was lower than that of HLA class II antibodies (43.2% vs. 51.3%, P = .006). The mean fluorescence intensities (MFI) of IgG-Luminex correlated with the MFI of C1q-Luminex for the same antibodies (Spearman correlation; class I, r = 0.665, P < .01; class II, r = 0.761, P < .01). Receiver operating characteristic (ROC) curve analysis showed that the MFIs of HLA antibodies by IgG-Luminex predicted their C1q-binding abilities (area under the curve [AUC] class I = 0.917; AUC class II = 0.927). Using MFI cutoff values of 8238 and 6754 in IgG-Luminex for HLA class I and class II antibodies, respectively, the sensitivity and specificity for C1q binding were 82.4% and 87.4% for class I antibodies and 90.9% and 82% for class II antibodies.
CONCLUSIONS: The MFI of HLA antibodies by IgG-Luminex predicts the complement-binding capability to a certain extent before transplantation.
Предметные рубрики MeSH
AdultAntibodiesComplement C1qComplement Fixation TestsFemaleFluorescenceFluorescent Antibody TechniqueGraft RejectionHLA AntigensHistocompatibility Antigens Class IHumansImmunoglobulin GKidney Failure, ChronicKidney TransplantationMaleMiddle AgedPredictive Value of TestsROC CurveReference ValuesRetrospective StudiesSensitivity and SpecificityWaiting Lists