MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2016.04.018

Медицинская библиотека · Transplantation proceedings · 2016

Prediction of Complement-Binding Capacity of HLA Antibodies Based on Mean Fluorescence Intensity.

Zhao J, Fu Y X, Yang T, Shen Z Y, Wu C L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Human leukocyte antigen (HLA) antibodies estimated by Luminex single-antigen beads, especially those that fix complement, are associated with antibody-mediated rejection and graft failure. However, the relationship between HLA antibody strength and complement-binding ability is controversial.

METHODS

Serum samples of 31 sensitized renal patients waiting for renal transplantation were retrospectively analyzed by IgG-Luminex to identify HLA antibodies and in parallel by C1q-Luminex to determine the complement binding of HLA antibodies.

RESULTS

The percentage of HLA class I antibodies binding with C1q was lower than that of HLA class II antibodies (43.2% vs. 51.3%, P = .006). The mean fluorescence intensities (MFI) of IgG-Luminex correlated with the MFI of C1q-Luminex for the same antibodies (Spearman correlation; class I, r = 0.665, P < .01; class II, r = 0.761, P < .01). Receiver operating characteristic (ROC) curve analysis showed that the MFIs of HLA antibodies by IgG-Luminex predicted their C1q-binding abilities (area under the curve [AUC] class I = 0.917; AUC class II = 0.927). Using MFI cutoff values of 8238 and 6754 in IgG-Luminex for HLA class I and class II antibodies, respectively, the sensitivity and specificity for C1q binding were 82.4% and 87.4% for class I antibodies and 90.9% and 82% for class II antibodies.

CONCLUSIONS

The MFI of HLA antibodies by IgG-Luminex predicts the complement-binding capability to a certain extent before transplantation.

Для цитирования: Zhao J, Fu Y X, Yang T, Shen Z Y, Wu C L. Prediction of Complement-Binding Capacity of HLA Antibodies Based on Mean Fluorescence Intensity.. Transplantation proceedings. 2016. DOI: 10.1016/j.transproceed.2016.04.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.