Diagnostic parameters and reliability of four rapid immunochromatographic tests for dengue 4.

Mata Veronica Elizabeth, Passos Sonia Regina Lambert, Santos Maria Angelica Borges Dos, Buonora Sibelle Nogueira, de Andrade Carlos Augusto Ferreira, Lima Monique da Rocha Queiroz, Costa Betina Moreira, Hökerberg Yara Hahr Marques

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Although performance of rapid immunochromatographic tests (RITs) for dengue virus (DENV) serotypes 1, 2 and 3 is relatively settled, evidence on accuracy of RITs for DENV-4 are based on studies with small sample sizes and with discrepant results.

OBJECTIVES

To assess accuracy and inter-observer agreement of RITs targeting dengue nonstructural protein-1 (NS1) antigen - Dengue NS1-Bioeasy™, Dengue NS1 Ag Strip-Bio-Rad™, IVB Dengue Ag NS1-Orangelife™ and Dengue NS1-K130-Bioclin™ in DENV-4 samples.

METHODS

Study sample (n = 324) included adults presenting at an emergency unit in Rio de Janeiro, Brazil, with fever of ≤72 h and two or more dengue symptoms. A serum sample from each patient was tested by each RIT. A positive reverse-transcription polymerase chain reaction was considered as the reference standard for dengue diagnosis. The diagnostic parameters analyzed for each RIT were sensitivity, specificity, positive and negative predictive values, and likelihood ratios. Each RIT was read by homogeneous (two junior nurses) or heterogeneous (one junior nurse and one senior biologist) pairs. Agreement was estimated by simple kappa with 95% confidence interval, positive (Ppos) and negative (Pneg) proportion concordance and prevalence and bias adjusted kappa, rated from poor (k < 0.0) to almost perfect (0.8 < k < 1.0), and perfect (k = 1).

RESULTS

NS1 RITs for DENV-4 diagnosis showed high specificity (95.9%-99.4%), but low sensitivity (14.7%-45.4%). Bioeasy™ had the best performance, with a positive likelihood ratio of 26.0 (95% CI: 8.4;81.0). Inter-observer agreement was almost perfect for all evaluated RITs. Mismatches in confirmed dengue were more common for the Bioclin™ (Ppos 88.3-90.0 %) and Orangelife™ (Ppos 91.7-94.1 %) tests.

CONCLUSIONS

For DENV-4, the tested RITs had high specificity, but lower sensitivity compared to published results for other serotypes. They should not be used for screening purposes. Different brands may have very different performances. This should be considered upon deciding of using RITs in DENV-4 outbreaks.

Для цитирования: Mata Veronica Elizabeth, Passos Sonia Regina Lambert, Santos Maria Angelica Borges Dos, Buonora Sibelle Nogueira, de Andrade Carlos Augusto Ferreira, Lima Monique da Rocha Queiroz, Costa Betina Moreira, Hökerberg Yara Hahr Marques. Diagnostic parameters and reliability of four rapid immunochromatographic tests for dengue 4.. The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases. 2020. DOI: 10.1016/j.bjid.2019.12.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.