Медицинская библиотека · JACC. Clinical electrophysiology · 2025

Microvolt Activation Alternans Identifies Conduction Velocity Heterogeneity and the Entrance Site of Ischemic Ventricular Tachycardia.

Denham Nathan C, Suszko Adrian M, Nemaire Masimba, Bhaskaran Abhishek, Massé Stéphane, Nanthakumar Kumaraswamy, Haïssaguerre Michel, Downar Eugene, Vigmond Edward, Chauhan Vijay S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Body surface microvolt QRS alternans has been shown to predict ventricular tachyarrhythmias in patients with cardiomyopathy; however, the mechanism is unclear.

OBJECTIVES

The aim of this study was to determine the spatiotemporal relationship of beat-to-beat bipolar electrogram (EGM) activation alternans (AA) to the ventricular tachycardia (VT) circuit and to surface QRS alternans.

METHODS

Intraoperative mapping during ventricular pacing and induced VT was performed in 9 patients with ischemic cardiomyopathy using a 112-bipole endocardial array. AA was quantified at EGM sites during pacing, timed to the surface QRS complex (intra vs post), correlated to local conduction velocity (CV), the location of the VT circuit, and surface QRS alternans. In silico modeling was performed to investigate the relationship between conduction disturbances and AA.

RESULTS

Intra-QRS and post-QRS AA was present in 8 of 9 patients with similar frequency (4.6% [Q1-Q3: 2.8%-8.3%] vs 3.5% [Q1-Q3: 1.0%-4.7%]; P = 0.77) and magnitude (192 μV [Q1-Q3: 72-246 μV] vs 470 μV [Q1-Q3: 270-601 μV]; P = 0.158). The presence of intra-QRS AA strongly correlated with the entrance of the VT circuit compared with remote regions (OR: 6.8; 95% CI: 3.7-12.5; P < 0.001). CV heterogeneity was the primary determinant of intra-QRS AA magnitude, in which each 0.1 increase in heterogeneity correlated with a 31-μV (95% CI: 3-59 μV) magnitude increase (P = 0.032). Intra-QRS AA magnitude strongly correlated with surface QRS alternans magnitude (r = 0.92, P = 0.001). Computer modeling supported AA sites representing <1-mm channels with 2:1 conduction block.

CONCLUSIONS

Microvolt intra-QRS AA in the bipolar EGM is a marker of CV heterogeneity that associates with the VT entrance and may guide VT ablation. Surface QRS alternans is a manifestation of intra-QRS AA and may inform risk stratification.

Для цитирования: Denham Nathan C, Suszko Adrian M, Nemaire Masimba, Bhaskaran Abhishek, Massé Stéphane, Nanthakumar Kumaraswamy, Haïssaguerre Michel, Downar Eugene, Vigmond Edward, Chauhan Vijay S. Microvolt Activation Alternans Identifies Conduction Velocity Heterogeneity and the Entrance Site of Ischemic Ventricular Tachycardia.. JACC. Clinical electrophysiology. 2025. DOI: 10.1016/j.jacep.2025.02.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.