DOI 10.1007/s10140-021-02005-1
The use of ultrasound in establishing COVID-19 infection as part of a trauma evaluation.
Аннотация
PURPOSE: The use of lung ultrasound for diagnosis of COVID-19 has emerged during the pandemic as a beneficial diagnostic modality due to its rapid availability, bedside use, and lack of radiation. This study aimed to determine if routine ultrasound (US) imaging of the lungs of trauma patients with COVID-19 infections who undergo extended focused assessment with sonography for trauma (EFAST) correlates with computed tomography (CT) imaging and X-ray findings, as previously reported in other populations.
METHODS
This was a prospective, observational feasibility study performed at two level 1 trauma centers. US, CT, and X-ray imaging were retrospectively reviewed by a surgical trainee and a board-certified radiologist to determine any correlation of imaging findings in patients with active COVID-19 infection.
RESULTS
There were 53 patients with lung US images from EFAST available for evaluation and COVID-19 testing. The overall COVID-19 positivity rate was 7.5%. COVID-19 infection was accurately identified by one patient on US by the trainee, but there was a 15.1% false-positive rate for infection based on the radiologist examination.
CONCLUSIONS
Evaluation of the lung during EFAST cannot be used in the trauma setting to identify patients with active COVID-19 infection or to stratify patients as high or low risk of infection. This is likely due to differences in lung imaging technique and the presence of concomitant thoracic injury.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.