MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2008.10.037

Медицинская библиотека · European journal of radiology · 2008

Pushable springcoil embolization of pseudoaneurysms caused by gluteal stab injuries.

Guven Koray, Rozanes Izzet, Ucar Adem, Poyanli Arzu, Yanar Hakan, Acunas Bulent

СтатьяПеревод в очереди

Аннотация

PURPOSE: To retrospectively review the outcomes of 21 patients with stab wounds to the gluteal region who underwent embolization for pseudoaneurysms causing active bleeding.

MATERIALS AND

METHODS

Between 1997 and 2007, 3 superior gluteal artery, 2 inferior gluteal artery and 16 deep femoral artery muscular branch pseudoaneurysms detected by digital subtraction angiography were selectively catheterized with diagnostic catheters with hydrophilic coating and embolized with pushable springcoils. 17 of the 21 pseudoaneurysms were located in a distal end of an artery where outflow vessels could not be depicted. The other 4 lesions were side wall injuries which required the placement of coils distal and proximal to the injury site.

RESULTS

Embolization was successful in controlling the bleeding in all of the patients. 16 patients required 1 or 2 coils, 4 patients required 3 coils and 1 patient required 5 coils. 2 patients had femoral puncture site hematomas which resolved spontaneously. 2 patients required surgical evacuation of large gluteal hematomas following the embolization because of symptoms second to mass effect. There were no procedure related major complications or mortality.

CONCLUSIONS

Our experience demonstrates that pushable coil embolization is a relatively simple, effective and economic method for the embolization of pseudoaneurysms caused by penetrating gluteal injuries. Experimenting with other embolization materials does not seem to be justified.

Для цитирования: Guven Koray, Rozanes Izzet, Ucar Adem, Poyanli Arzu, Yanar Hakan, Acunas Bulent. Pushable springcoil embolization of pseudoaneurysms caused by gluteal stab injuries.. European journal of radiology. 2008. DOI: 10.1016/j.ejrad.2008.10.037.