MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3892/etm.2017.5572

Медицинская библиотека · Experimental and therapeutic medicine · 2017

A pilot study of a cardiovascular virtual endoscopy system based on multi-detector computed tomography in diagnosing tetralogy of Fallot in pediatric patients.

Yao Li-Ping, Zhang Li, Mei Ju, Ding Fang-Bao, Li Hui-Ming, Ding Ming, Yang Xin, Li Xiao-Ming, Sun Kun

СтатьяПеревод в очереди

Аннотация

The present study aimed to investigate the capabilities of the cardiovascular virtual endoscopy (VE) system in diagnosing tetralogy of Fallot (TOF) and performing measurements. A total of 37 patients underwent two-dimensional echocardiography (2-DE) and multi-detector computed tomography (MDCT) examinations. The obtained MDCT images were applied to a cardiovascular VE system. Diagnostic time by VE was first studied and compared with MDCT. Subsequently, with surgical findings as the ground truth, the capabilities of VE, 2-DE and MDCT in diagnosing TOF and its complications were investigated. Additionally, measurements on aorta overriding ratio and diameters for the left pulmonary artery, right pulmonary artery and right ventricular outflow tract by 2-DE and VE were analyzed. Diagnostic time by VE was significantly shorter than MDCT (188±42 vs. 303±42 sec, respectively; P<0.0001). VE, MDCT and 2-DE demonstrated comparable diagnostic rates of TOF (35/37 vs. 34/37 vs. 32/37, respectively; P>0.05). Similar findings were demonstrated in diagnosing complications of the muscular ventricular septal defects, patent ductus arteriosus, vagus subclavian artery, right arch, double superior vena cava and pulmonary artery. Furthermore, in diagnosing the atrial septal defect, 2-DE outperformed MDCT and VE (accuracy, 100 vs. 81 vs. 73%, respectively; all P<0.05). In performing relevant measurements, VE outperformed MDCT and 2-DE, particularly in accessing aorta overriding ratios with no intra-operator difference (P=0.3770) and high consistency (r=0.916). In conclusion, cardiovascular VE was demonstrated to have acceptable accuracy in diagnosing TOF, and possess advantages in shortening the diagnostic time and in performing measurements.

Для цитирования: Yao Li-Ping, Zhang Li, Mei Ju, Ding Fang-Bao, Li Hui-Ming, Ding Ming, Yang Xin, Li Xiao-Ming, Sun Kun. A pilot study of a cardiovascular virtual endoscopy system based on multi-detector computed tomography in diagnosing tetralogy of Fallot in pediatric patients.. Experimental and therapeutic medicine. 2017. DOI: 10.3892/etm.2017.5572.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.