The effect of impact duration on the axial fracture tolerance of the isolated tibia during automotive and military impacts.

Martinez Alberto A, Chakravarty Avery B, Quenneville Cheryl E

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Axial impacts to the lower leg during debilitating events such as frontal automotive collisions and military underbody blasts can cause significant injuries to the tibia. Several studies have conducted axial impact tests to determine the injury limits of the lower leg, mostly focused on automotive intrusions, resulting in an established force criterion for injury assessments. Due to the viscoelastic properties of bone, it remains unclear whether results from automotive experiments can be applied to higher-rate military blasts. Twelve male isolated cadaveric tibias (from six pairs, mean age: 62 ± 8 years) were subjected to axial impact loads using a custom-built pneumatic impactor, with one specimen from each pair tested at velocity and impact durations representative of a military blast condition, and the contralateral under conditions representing an automotive collision. Impacts were applied in increasing levels of intensity (defined using energy levels) until fracture occurred. Fracture risk was influenced by projectile velocity, kinetic energy, impulse, and load rate, and there was a significant difference in peak force (p = 0.023), impulse (p = 0.09), and load rate (p = 0.025) between the automotive and military test conditions causing fracture. A 10% risk of fracture corresponded to an impact force of 9.0kN for the automotive condition and 12.2kN for the military condition. These results suggest that fracture tolerances developed in studies that simulate automotive impacts cannot be directly applied to military impacts of shorter duration. The number of factors identified to predict injury also suggests that fracture is not controlled by a single variable.

Для цитирования: Martinez Alberto A, Chakravarty Avery B, Quenneville Cheryl E. The effect of impact duration on the axial fracture tolerance of the isolated tibia during automotive and military impacts.. Journal of the mechanical behavior of biomedical materials. 2017. DOI: 10.1016/j.jmbbm.2017.11.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.