DOI 10.1016/j.ejrad.2008.09.015

Медицинская библиотека · European journal of radiology · 2009

Central venous infusion port inserted via high versus low jugular venous approaches: retrospective comparison of outcome and complications.

Park Hong Suk, Kim Young Il, Lee Sang Hyun, Kim Jung Im, Seo Hyobin, Lee Sang Min, Lee Youkyung, Lim Min Kyung, Park Young Suk

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To retrospectively compare immediate and long-term outcome of central venous infusion port inserted via right high versus low jugular vein approaches.

MATERIALS AND

METHODS

The study included 163 patients (125 women patients, 38 men patients; age range, 18-79 years; mean age, 53 years); 142 patients underwent port insertion with low jugular vein approach and 21 patients with high jugular vein approach. The causes of high jugular vein puncture were metastatic lymphadenopathy (n=7), operation scar (n=6), radiation scar (n=5), failure of low jugular vein puncture (n=2), and abnormal course of right subclavian artery (n=1). Medical records and radiologic studies were reviewed retrospectively to determine and compare the outcome and the occurrence of complication related to port.

RESULTS

The procedure-related complications were all minor (n=14, 8.6%) in both groups; hematoma (n=4, 2.8% in low jugular puncture group and n=1, 4.8% in high jugular puncture group, p=0.6295), air embolism (n=2, 1.4% in low jugular puncture group and n=0 in high jugular puncture group, p=0.5842) and minor bleeding (n=5, 3.5% in low jugular vein puncture group and n=2, 9.5% in high jugular vein puncture group, p=0.2054). The average length of follow-up was 431 days for low jugular vein puncture group and 284 days for high jugular vein puncture group. The difference between two groups was significant (p=0.0349). The reasons for catheter removal were patients' death (59 in low jugular puncture group and 14 in high jugular puncture group, p=0.0465), suspected infection (11 in low jugular vein puncture group and 2 in high jugular vein puncture group, p=0.8242), catheter occlusion (four in low jugular vein puncture group and one in high jugular vein puncture group, p=0.6583). The catheter tip migrated upward an average of 1.86 cm (range, -0.5 to 5.0 cm) in low jugular vein puncture group and 1.56 cm (range, 0-3.6 cm) in high jugular vein puncture group and there was no significant difference (p=0.4232).

CONCLUSIONS

Right high jugular vein approach can be a feasible alternative to right low jugular vein approach.

Для цитирования: Park Hong Suk, Kim Young Il, Lee Sang Hyun, Kim Jung Im, Seo Hyobin, Lee Sang Min, Lee Youkyung, Lim Min Kyung, Park Young Suk. Central venous infusion port inserted via high versus low jugular venous approaches: retrospective comparison of outcome and complications.. European journal of radiology. 2009. DOI: 10.1016/j.ejrad.2008.09.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.