OBJECTIVE

The hybrid stage I procedure is an alternative palliative strategy for patients with hypoplastic left heart syndrome who traditionally have undergone the Norwood operation. At our institution, the hybrid stage I procedure is employed only for patients with high operative risk. Our objective was to describe our use of a pressure guidewire during the hybrid stage I procedure to assess quantitatively pulmonary artery band adequacy.

DESIGN

After reviewing the charts on all high-risk patients who underwent a hybrid stage I procedure at our institution, we compared two groups of patients: those who underwent the standard hybrid stage I palliation (standard cohort) and those with pressure wire-facilitated assessment of distal branch pulmonary artery pressure (pressure wire cohort) to evaluate the impact of pressure guidewire use on procedural risk, radiation time, patient outcomes, and need for reoperation for pulmonary artery band adjustment.

RESULTS

The pressure guidewire was used in 8 of 14 patients at the time of hybrid stage I procedure and was successful and without complication in all attempts. In the standard cohort, 67% of patients needed reoperation for pulmonary artery band adjustment, compared to 12.5% of patients in the pressure wire cohort (P =.09). Procedure time, radiation exposure, and survival to hospital discharge were not different between groups.

CONCLUSIONS

This novel use of a pressure guidewire to assess quantitatively pulmonary artery band adequacy at the time of placement is feasible, safe and may decrease the need for reoperation for pulmonary artery band adjustment.

Для цитирования: Zampi Jeffrey D, Hirsch Jennifer C, Goldstein Bryan H, Armstrong Aimee K. Use of a pressure guidewire to assess pulmonary artery band adequacy in the hybrid stage I procedure for high-risk neonates with hypoplastic left heart syndrome and variants.. Congenital heart disease. 2012. DOI: 10.1111/chd.12005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.