OBJECTIVE

The aim of this study was to evaluate sequences that are established at lower magnetic field strengths for lumbar spine imaging at 7 Tesla (7 T) MR imaging.

MATERIALS AND

METHODS

The lumbar spine of five healthy volunteers and a patient with spina bifida and meningocele were evaluated at 7 T. The examination included a T2-TSE (turbo spin echo), a 3D-DESS (double-echo steady-state sequence), a 3D-CISS (constructive interference in steady-state sequence), and a 3D-VIBE (volumetric interpolated breath hold examination) sequence. Imaging quality was evaluated by two raters on a three-level scale. The assessment included visualization of intraforaminal structures, the cauda equina, facet joints, and any abnormalities. Contrast ratios for intervertebral discs/vertebral bodies, vertebral bodies/cerebrospinal fluid (CSF) and CSF/spinal cord were calculated.

RESULTS

The 3D-VIBE sequence provided best differentiation between intraforaminal structures. Visualization of the facet joints was reliable with VIBE, DESS, and CISS. Individual nerve roots of the cauda equina could only be delineated with the 3D-CISS sequence. CISS and DESS provided good contrast between vertebral bodies and intervertebral discs. Contrast between CSF and vertebral bodies was most pronounced for the T2-TSE sequence. Sufficient contrast between CSF and the spinal cord was only achieved with the T2-TSE sequence. VIBE and DESS sequences demonstrated best the bony malformations. Visualization of the meningocele was only possible with the 3D-CISS sequence.

CONCLUSION

At 7 T most structures of the lumbar spine were visualized with a combination of sequences. At present, imaging quality is not superior to 1.5 T or 3 T, precluding routine clinical use.

Для цитирования: Grams Astrid E, Kraff Oliver, Umutlu Lale, Maderwald Stefan, Dammann Philipp, Ladd Mark E, Forsting Michael, Gizewski Elke R. MRI of the lumbar spine at 7 Tesla in healthy volunteers and a patient with congenital malformations.. Skeletal radiology. 2011. DOI: 10.1007/s00256-011-1197-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.