MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xphs.2021.05.017

Медицинская библиотека · Journal of pharmaceutical sciences · 2021

Identification of an Oxidizing Leachable from a Clinical Syringe Rubber Stopper.

Schröter Ariane, Peter Sonja, Mahler Hanns-Christian, Zerr Andreas, Danton Ombeline, Chalus Pascal, Koulov Atanas V, Huwyler Jörg, Jahn Michael

СтатьяПеревод в очереди

Аннотация

Leaching of toxic or reactive chemicals from polymeric materials can adversely affect the quality and safety of biopharmaceuticals. It was therefore the aim of the present study to analyze leachables from a disposable clinical administration syringe using a polysorbate-containing surrogate solution and to assess their chemical reactivity. Analytical methods did include (headspace) GC-MS, Fourier-transform-infrared spectroscopy, a ferrous oxidation-xylenol orange assay, and nuclear magnetic resonance analysis. In the syringe leachables solution, the carcinogenic 1,1,2,2-tetrachloroethane (TCE) was detected in concentrations above the ICH M7-derived analytical evaluation threshold. TCE was shown to be an oxidation product of dichloromethane used during sample preparation. Since TCE was only isolated from incubations with the contained rubber stopper, we hypothesized that a stopper-derived leachable acted as a reactive oxidant promoting this chemical reaction. Subsequently, the leachable was identified to be the polymerization initiator Luperox® 101. Combining different analytical approaches led to the structural elucidation of a chemical reactive oxidant, which has the potential to interact and alter drug products. We conclude that chemically reactive compounds, such as the newly identified rubber stopper leachable Luperox® 101, may be of concern and therefore should be routinely considered if a prolonged exposure of polymers with drug products can be anticipated.

Для цитирования: Schröter Ariane, Peter Sonja, Mahler Hanns-Christian, Zerr Andreas, Danton Ombeline, Chalus Pascal, Koulov Atanas V, Huwyler Jörg, Jahn Michael. Identification of an Oxidizing Leachable from a Clinical Syringe Rubber Stopper.. Journal of pharmaceutical sciences. 2021. DOI: 10.1016/j.xphs.2021.05.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.