Robotic versus electromagnetic bronchoscopy for pulmonary leslon assessment using integrated intraprocedural imaging: Study protocol for the reliant 2 trial.

Paez Rafael, Ratwani Ankush P, Duke Jennifer D, Bridwell Greta, Leonard Kaele, Katsis James M, Pickering Edward M, Thiboutot Jeffrey, Chen Heidi, Chen Sheau-Chiann, Shojaee Samira, Yarmus Lonny, Lentz Robert J, Maldonado Fabien, Interventional Pulmonary Outcomes Group

СтатьяПротокол клинического исследованияПеревод в очереди

Аннотация

BACKGROUND

Robotic assisted bronchoscopy (RAB) and electromagnetic navigational bronchoscopy (ENB) are two approaches to biopsy peripheral pulmonary lesions (PPLs). A recently completed cluster randomized controlled trial, RELIANT (NCT05705544), showed no difference in diagnostic yield between these two modalities. The ENB platform used in RELIANT included integrated digital tomosynthesis, allowing for real-time assessment of PPL location for more precise targeting at the time of biopsy. RAB has since been integrated with cone beam computed tomography (CBCT) to accomplish the same intraprocedural correction. It is unclear if the diagnostic yield of RAB with integrated CBCT (RAB-CBCT) is superior to ENB with integrated digital tomosynthesis (ENB-DT).

METHODS

Robotic versus Electromagnetic Bronchoscopy for Pulmonary LesIon AssessmeNT using integrated intraprocedural imaging (RELIANT 2) is an investigator-initiated, multicenter, open label, superiority, cluster randomized trial. At each participating institution, procedural rooms are randomly assigned to either RAB-CBCT or ENB-DT, with each procedure room-day considered a cluster. All adult patients undergoing navigational bronchoscopy for evaluation of PPL(s) are eligible. Allocation is concealed from schedulers, proceduralists, and patients until the morning of procedure when each room is randomized to a platform. The primary endpoint is the diagnostic yield, defined as the proportion of cases yielding a specific benign or malignant diagnosis per current ATS/ACCP definition. Secondary and safety endpoints include procedure duration and procedural complications. Enrollment began on November 11, 2024 and is expected to enroll approximately 440 patients in 220 clusters.

DISCUSSION: RELIANT 2 is an ongoing cluster randomized trial comparing the diagnostic yield of RAB-CBCT to that of ENB-DT in patients undergoing bronchoscopy to biopsy PPLs. This trial will help address some of the limitations of the recently published RELIANT trial. Trial registration The trial was registered in ClinicalTrials.gov (NCT06654271) on October 21, 2024, prior to patient enrollment.

Для цитирования: Paez Rafael, Ratwani Ankush P, Duke Jennifer D, Bridwell Greta, Leonard Kaele, Katsis James M, Pickering Edward M, Thiboutot Jeffrey, Chen Heidi, Chen Sheau-Chiann, Shojaee Samira, Yarmus Lonny, Lentz Robert J, Maldonado Fabien, Interventional Pulmonary Outcomes Group. Robotic versus electromagnetic bronchoscopy for pulmonary leslon assessment using integrated intraprocedural imaging: Study protocol for the reliant 2 trial.. PloS one. 2025. DOI: 10.1371/journal.pone.0327611.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.