MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2017.10.018

Медицинская библиотека · International journal of cardiology · 2017

Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.

Martens Pieter, Verbrugge Frederik H, Boonen Levinia, Nijst Petra, Dupont Matthias, Mullens Wilfried

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

AIMS: Guidelines advocate down-titration of loop diuretics in chronic heart failure (CHF) when patients have no signs of volume overload. Limited data are available on the expected success rate of this practice or how routine diagnostic tests might help steering this process.

METHODS AND

RESULTS

Fifty ambulatory CHF-patients on stable neurohumoral blocker/diuretic therapy for at least 3months without any clinical sign of volume overload were prospectively included to undergo loop diuretic down-titration. All patients underwent a similar pre-down-titration evaluation consisting of a dyspnea scoring, physical examination, transthoracic echocardiography (diastolic function, right ventricular function, cardiac filling pressures and valvular disease), blood sample (serum creatinine, plasma NT-pro-BNP and neurohormones). Loop diuretic maintenance dose was subsequently reduced by 50% or stopped if dose was ≤40mg furosemide equivalents. Successful down-titration was defined as a persistent dose reduction after 30days without weight increase >1.5kg or new-onset symptoms of worsening heart failure. At 30-day follow-up, down-titration was successful in 62% (n=31). In 12/19 patients exhibiting down-titration failure, this occurred within the first week. Physical examination, transthoracic echocardiography and laboratory analysis had limited predictive capability to detect patients with down-titration success/failure (positive likelihood-ratios below 1.5, or area under the curve [AUC] non-statically different from AUC=0.5).

CONCLUSION

Loop diuretic down-titration is feasible in a majority of stable CHF patients in which the treating clinician felt continuation of loops was unnecessary to sustain euvolemia. Importantly, routine diagnostics which suggest euvolemia, have limited diagnostic impact on the post-test probability.

Для цитирования: Martens Pieter, Verbrugge Frederik H, Boonen Levinia, Nijst Petra, Dupont Matthias, Mullens Wilfried. Value of routine investigations to predict loop diuretic down-titration success in stable heart failure.. International journal of cardiology. 2017. DOI: 10.1016/j.ijcard.2017.10.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.