BACKGROUND

The visualization of the glottis may be inadequate in morbidly obese patients when a standard Macintosh blade laryngoscope (MCL) is used. The Vie Scope® (VS) is a novel type laryngoscope consisting of a straight, enclosed, illuminated tube that offers intubation via a bougie using the paraglossal technique. In this prospective, nonrandomized comparative study, we tested the research hypothesis that the VS may improve visualization of the glottic larynx in comparison to the MCL.

MATERIALS AND

METHODS

After obtaining institutional ethics committee approval, 60 morbidly obese patients (BMI >40 kg/m2) undergoing elective non-head and neck surgery were included in the study. After induction of general anesthesia (GA), the glottic visualization was performed using the two laryngoscopes in succession, first MCL size 3 or 4 followed by the VS and was assessed using the modified Cormack-Lehane scale. Tracheal intubation was performed using the VS The first pass intubation success and the total success rate was recorded only for the VS Intubation time was not measured because of the paired study design.

RESULTS AND DISCUSSION: Mean demographic data included: age 41.9±8.2 years, height 171.2±10.2 cm, weight 129.9±21.6 kg, BMI 44.95±3.85 kg/m2. Using MCL, Cormack-Lehane grade 1 was observed in 36 (60%) cases; grade 2 in 7/60 (11.6%); grade 3 in 13/60 (21.7%); and grade 4 in 4/60 (6.7%). Poor laryngeal views represented by grades 3 and 4 were observed in 28.4% of patients with the MCL. Grades obtained with the VS were all grade 1 (100%). The first attempt intubation success was in 58/60 (96.7%) with the VS. No complications were observed.

CONCLUSION

The Vie Scope® laryngoscope, using the paraglossal technique of tracheal intubation, significantly improves visualization of the vocal cords in morbidly obese patients compared to the standard Macintosh laryngoscope.

Для цитирования: Gaszynski Tomasz, Michalek Pavel, Ratajczyk Pawel. A Prospective Comparative Study of Laryngeal Glottic View Using the Vie Scope® versus Standard Macintosh Laryngoscope in Morbidly Obese Patients.. Therapeutics and clinical risk management. 2023. DOI: 10.2147/tcrm.s377585.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.