MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/imi.0b013e31815887e0

Медицинская библиотека · Innovations (Philadelphia, Pa.) · 2007

Thoracic aortic stent grafting in patients with connective tissue disorders: a word of caution.

Mohammadi Siamak, Normand Jean-Pierre, Voisine Pierre, Dagenais François

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

: Use of thoracic Stent-graft in patients with connective tissue disorders (CTD) remains limited. We herein report 3 patients with CTD who underwent stent grafting.

METHODS AND

RESULTS

: Case 1; A male Marfan patient was operated for thoraco-abdominal aneurysm. On computed tomography (CT), large false aneurysm at the proximal anastomosis was documented which was excluded with a 30 mm Talent stent-graft with 10-15% oversize. Case 2; A female with Ehlers-Danlos syndrome had undergone resection of descending aortic thoracic aneurysm presented with an enlarging aneurysm distal to the graft. Three Talent stent-grafts (15% oversize) were deployed with balloon dilatation to exclude the aneurysm. The immediate postoperative period was complicated by an extensive intramural hematoma of the descending aorta with hemothorax, managed conservatively. Case 3; A female Marfan patient had undergone Bentall procedure and mitral repair followed with resection of the proximal descending aorta. Three months later a false aneurysm at the distal anastomosis was treated with a 24 mm Valiant stent-graft (30% oversize). Aortic dissection distal to stent was documented on the early postoperative CT. The dissected aneurysm enlarged significantly with a type I distal endoleak during follow-up. Concomitantly, the patient presented a class III dyspnea owing to a severe mitral regurgitation. The patient underwent a successful MVR and stent-graft explantation with replacement of the descending aorta.

CONCLUSION

: Significant complications supervened when stent-grafts were deployed in native aorta. We thus recommend that deploying a stent-graft in a CTD diseased aorta should be considered a relative contraindication. In cases with prohibitive or high risk surgery, use of a stent-graft with minimal radial force and minimal oversizing without balloon dilatation should be considered.

Для цитирования: Mohammadi Siamak, Normand Jean-Pierre, Voisine Pierre, Dagenais François. Thoracic aortic stent grafting in patients with connective tissue disorders: a word of caution.. Innovations (Philadelphia, Pa.). 2007. DOI: 10.1097/imi.0b013e31815887e0.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.