BACKGROUND

Apheresis-based desensitization allows for successful transplantation across major immunological barriers. For donor-specific antibody (DSA)- and/or crossmatch-positive transplantation, however, it has been shown that even intense immunomodulation may not completely prevent antibody-mediated rejection (ABMR).

METHODS

In this study, we evaluated transplant outcomes in 101 DSA+ deceased donor kidney transplant recipients (transplantation between 2009 and 2013; median follow-up: 24 months) who were subjected to immunoadsorption (IA)-based desensitization. Treatment included a single pre-transplant IA session, followed by anti-lymphocyte antibody and serial post-transplant IA. In 27 cases, a positive complement-dependent cytotoxicity crossmatch (CDCXM) was rendered negative immediately before transplantation. Seventy-four of the DSA+ recipients had a negative CDCXM already before IA.

RESULTS

Three-year death-censored graft survival in DSA+ patients was significantly worse than in 513 DSA- recipients transplanted during the same period (79 versus 88%, P = 0.008). Thirty-three DSA+ recipients (33%) had ABMR. While a positive baseline CDCXM showed only a trend towards higher ABMR rates (41 versus 30% in CDCXM- recipients, P = 0.2), DSA mean fluorescence intensity (MFI) in single bead assays significantly associated with rejection, showing 20 versus 71% ABMR rates at <5000 versus >15 000 peak DSA MFI. The predictive value of MFI was moderate, with the highest accuracy at a median of 13 300 MFI (after cross-validation: 0.72). Other baseline variables, including CDC assay results, human leukocyte antigen mismatch, prior transplantation or type of induction treatment, did not add independent predictive information.

CONCLUSIONS

IA-based desensitization failed to prevent ABMR in a considerable number of DSA+ recipients. Assessing DSA MFI may help stratify risk of rejection, supporting its use as a guide to organ allocation and individualized treatment.

Для цитирования: Schwaiger Elisabeth, Eskandary Farsad, Kozakowski Nicolas, Bond Gregor, Kikić Željko, Yoo Daniel, Rasoul-Rockenschaub Susanne, Oberbauer Rainer, Böhmig Georg A. Deceased donor kidney transplantation across donor-specific antibody barriers: predictors of antibody-mediated rejection.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2016. DOI: 10.1093/ndt/gfw027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.