Stapling for wound dehiscence after cardiac implantable electronic device implantation.

Habash Fuad, Paydak Ozan, Pothineni Naga Venkata, Card Peyton, Sewani Asif

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Wound dehiscence (WD) has been reported as a complication in 0.3% of cardiac implantable electronic device (CIED) procedures. Stapling has not previously been reported as a treatment modality for WD. Presently described is the experience of a single center with WD and its management.

METHODS

A retrospective chart review of all patients who underwent CIED implantation between 2009 and 2016, a total of 759 devices, was performed.

RESULTS

There were a total of 11 (1.4%) patients with WD. The majority 9/11 patients were female, 5 of 11 (45.5%) had diabetes, and 2 of the 11 patients were immunocompromised due to recent chemotherapy. WD occurred in 6 patients after generator change, in 2 patients after a biventricular device upgrade, in 1 patient after biventricular implantable cardioverter defibrillator (ICD) implantation, in 1 patient after dual-chamber pacemaker implantation, and in 1 patient after subcutaneous ICD implantation. The median time of WD was 6 weeks post procedure (range: 1-20 weeks). In all of the patients, wound stapling was performed under sterile conditions after administering intravenous narcotic analgesics. Eight patients received intravenous antibiotics and all patients received at least 2 weeks of oral antibiotics. Blood cultures were negative in 8/11 (72.7%) patients. However, the wound cultures in 5 patients were positive. The staples were removed in a median of 16 days (range: 9-36 days). All of these patients were successfully treated with stapling and none of the devices required extraction.

CONCLUSION

Stapling under sterile conditions may be an acceptable treatment strategy to manage WD after device implantation. This can be performed as an outpatient procedure and can help avoid unnecessary device extraction.

Для цитирования: Habash Fuad, Paydak Ozan, Pothineni Naga Venkata, Card Peyton, Sewani Asif. Stapling for wound dehiscence after cardiac implantable electronic device implantation.. Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir. 2018. DOI: 10.5543/tkda.2018.57059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.