MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-18325-y

Медицинская библиотека · Scientific reports · 2025

Eco-friendly spectrofluorimetric and HPLC-fluorescence methods for simultaneous determination of melatonin and zolpidem in pharmaceuticals.

Abo Elkheir Shrouk M, Nasr Jenny Jeehan M, Walash Mohamed I, Zeid Abdallah M

СтатьяПеревод в очереди

Аннотация

Two eco-friendly, facile, rapid, and highly sensitive analytical methodologies were developed for the concurrent estimation of melatonin and zolpidem tartrate in raw materials and dosage forms. The first approach is a green first derivative synchronous spectrofluorimetric method (Method I), utilizing a wavelength interval (Δλ) of 60 nm and capturing derivative signals at 265.0 nm and 339.0 nm for melatonin and zolpidem, respectively. Method I exhibited excellent linearity over the ranges of 8.0-70.0 ng/mL for melatonin and 10.0-80.0 ng/mL for zolpidem, with detection limits of 1.62 ng/mL and 1.19 ng/mL. The second method (Method II) involves high-performance liquid chromatography coupled with fluorescence detection (HPLC-FD), employing a C18 column and a mobile phase of methanol:0.05% triethylamine (70:30, v/v, pH 5.5) at a flow rate of 1.0 mL/min. Fluorescence detection was performed at 383 nm following excitation at 243 nm. This method achieved linearity within 150.0-1500.0 ng/mL for melatonin and 50.0-700.0 ng/mL for zolpidem, with detection limits of 18.87 ng/mL and 8.86 ng/mL, respectively. Both methods were rigorously validated in accordance with ICH Q2(R1) guidelines, demonstrating high accuracy, precision, and robustness in analyzing commercial dosage forms. Greenness and sustainability were quantitatively assessed using the AGREE and eco-scale metrices, while method applicability and performance were evaluated using the Blue Applicability Grade Index (BAGI), affirming both techniques as efficient and environmentally sustainable tools for routine quality control.

Для цитирования: Abo Elkheir Shrouk M, Nasr Jenny Jeehan M, Walash Mohamed I, Zeid Abdallah M. Eco-friendly spectrofluorimetric and HPLC-fluorescence methods for simultaneous determination of melatonin and zolpidem in pharmaceuticals.. Scientific reports. 2025. DOI: 10.1038/s41598-025-18325-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.