MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-0736(86)81059-7

Медицинская библиотека · Journal of electrocardiology · 1986

Exercise testing and thallium-201 myocardial perfusion scintigraphy in the clinical evaluation of patients with Wolff Parkinson White syndrome.

Poyatos M E, Suarez L, Lerman J, Guibourg H, Camps J, Perosio A

СтатьяПеревод в очереди

Аннотация

In 58 patients with Wolff Parkinson White syndrome (WPW), we performed exercise stress testing in order to investigate the incidence of normalization of the auriculo-ventricular conduction and the ST-segment changes. For a more accurate evaluation of the latter, exercise and redistribution radionuclide images with Thallium-201 were obtained in 18 cases. Forty-nine had type A and nine had type B of WPW. Forty-eight had permanent, four had alternant and six had no pre-excitation (PE) when they started the test. Mean maximal functional capacity, mean maximal heart rate and mean maximal double product were not different when compared to an age-matched control group. Of the 48 patients who began the test with PE, in 23 (48%) it disappeared while PE persisted in 25 (52%). In 16 cases the disappearance of the PE was sudden and in seven it was progressive. Pre-excitation persisted in 39.5% of patients with type A and in 88.8% with type B (p less than 0.01). ST-segment depression was observed in 76.6% of patients with PE and in 28.6% of cases without PE (p less than 0.01). ST-segment depression occurred in 44.8% of patients with type A and in 100% of cases with type B (p less than 0.05). Transient abnormal Thallium-201 scans were observed in 62.5% of patients without PE and in 20% with PE. No patients showed exertional arrhythmias. This study suggests the possibility of measuring the duration of the refractory period of the accessory pathway in those patients in which the PE disappears suddenly, at a given heart rate.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Poyatos M E, Suarez L, Lerman J, Guibourg H, Camps J, Perosio A. Exercise testing and thallium-201 myocardial perfusion scintigraphy in the clinical evaluation of patients with Wolff Parkinson White syndrome.. Journal of electrocardiology. 1986. DOI: 10.1016/s0022-0736(86)81059-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.