Rationale and design of the NEO-NORMAL-AF study examination of the usefulness of implantable loop recorder for arrhythmia detection including atrial fibrillation in heart failure with non-reduced ejection fraction cases: a pilot study.

Sugiura Junichi, Kasama Syu, Ueda Tomoya, Nishida Taku, Kawata Hiroyuki, Horii Manabu, Ozu Naoki, Kasahara Masato, Saito Yoshihiko

СтатьяПоддержка исследования: вне правительства СШАПротокол клинического исследованияПеревод в очереди

Аннотация

INTRODUCTION

The incidence of arrhythmia in heart failure with non-reduced ejection fraction (HFnon-rEF) in patients who have a history of hospitalisation is unclear. The aim of this study is to investigate the usefulness of an implantable loop recorder (ILR) for arrhythmia detection including atrial fibrillation (AF) in HFnon-rEF patients after discharge.

METHODS AND ANALYSIS: This is a multicentre single arm study to evaluate the usefulness of ILR for detecting arrhythmia. The eligible patients are HFnon-rEF patients (left ventricular ejection fraction ≥40%) aged ≥20 years with a history of hospitalisation. The ILR will be implanted for qualified patients, and ECGs will be monitored and recorded for 1 year to check for arrhythmias. The primary endpoint is new-onset 6 min or more persistent AF detected by ILR. Secondary endpoints are 30 s or more persistent supraventricular tachycardia and ventricular tachycardia, 3 s or more persistent pause, bradycardia with 40 beats per minutes or lower heart rate, AF burden, all-cause death, cardiovascular death, hospital readmission due to exacerbation of HF, acute coronary syndrome, ischaemic or haemorrhagic stroke, non-pharmacological therapy such as pacemaker implantation and ablation.

CONCLUSIONS

This study is expected to provide valuable findings regarding arrhythmia in HFnon-rEF patients, and elucidate a potential new therapeutic approach for HFnon-rEF.

TRIAL REGISTRATION NUMBER: This trial has been registered in the Japan Registry of Clinical Trials (jRCT) (Trial Registration: jRCTs052210060).

Для цитирования: Sugiura Junichi, Kasama Syu, Ueda Tomoya, Nishida Taku, Kawata Hiroyuki, Horii Manabu, Ozu Naoki, Kasahara Masato, Saito Yoshihiko. Rationale and design of the NEO-NORMAL-AF study examination of the usefulness of implantable loop recorder for arrhythmia detection including atrial fibrillation in heart failure with non-reduced ejection fraction cases: a pilot study.. Open heart. 2023. DOI: 10.1136/openhrt-2022-002193.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.