Journal of cardiovascular electrophysiology · 2025
Pulsed-Field Ablation for Persistent Atrial Fibrillation in EU-PORIA Registry.
СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hirokami Jun, Chun Kyoung Ryul Julian, Bordignon Stefano, Tohoku Shota, Neven Kars, Reichlin Tobias, Blaauw Yuri, Hansen Jim, Adelino Raquel, Ouss Alexandre, Füting Anna, Roten Laurent, Mulder Bart A, Ruwald Martin H, Mené Roberto, van der Voort Pepijn, Reinsch Nico, Kueffer Thomas, Boveda Serge, Albrecht Elizabeth M, Schmidt Boris
Аннотация
BACKGROUND: Real-life data on efficacy and safety of pulsed-field ablation (PFA) using the pentaspline multi-electrode catheter in symptomatic atrial fibrillation (AF) patients is still scarce.
OBJECTIVE: This study aims to assess the efficacy and safety of PFA in patients with persistent AF.
METHODS: Data from early commercial use across seven European centers were collected in a registry. To confirm the efficacy and safety of extra pulmonary vein (PV) ablation, patients were categorized into two groups: those undergoing pulmonary vein isolation (PVI) alone and those receiving additional ablation. Procedural and follow-up data were collected.
RESULTS: The study included 448 patients (347 PVI only, 101 PVI + α). In the PVI + α group, extra PV ablation included left atrial posterior wall isolation (87%), mitral isthmus ablation (37%), and cavo-tricuspid isthmus ablation (3%). At 1-year follow-up, the PVI only group showed significantly fewer atrial tachyarrhythmia recurrences compared to PVI + α group (69% vs. 56%, p = 0.013). While AF recurrence did not significantly differ (25% vs. 28%, p = 0.713), PVI + α group had a significantly higher atrial tachycardia recurrence (8% vs. 22%, p < 0.001). Major complications occurred in 2.0% versus 1.0% (PVI only vs. PVI + α), including pericardial tamponade (6 vs. 0; p = 0.345) and stroke (1 vs. 1; p = 0.400).
CONCLUSIONS: PVI plus extra PV ablation using a pentaspline PFA catheter is associated with a higher incidence of atrial tachycardia recurrences. For persistent AF, a simpler approach of performing only PVI may be more effective.
OBJECTIVE: This study aims to assess the efficacy and safety of PFA in patients with persistent AF.
METHODS: Data from early commercial use across seven European centers were collected in a registry. To confirm the efficacy and safety of extra pulmonary vein (PV) ablation, patients were categorized into two groups: those undergoing pulmonary vein isolation (PVI) alone and those receiving additional ablation. Procedural and follow-up data were collected.
RESULTS: The study included 448 patients (347 PVI only, 101 PVI + α). In the PVI + α group, extra PV ablation included left atrial posterior wall isolation (87%), mitral isthmus ablation (37%), and cavo-tricuspid isthmus ablation (3%). At 1-year follow-up, the PVI only group showed significantly fewer atrial tachyarrhythmia recurrences compared to PVI + α group (69% vs. 56%, p = 0.013). While AF recurrence did not significantly differ (25% vs. 28%, p = 0.713), PVI + α group had a significantly higher atrial tachycardia recurrence (8% vs. 22%, p < 0.001). Major complications occurred in 2.0% versus 1.0% (PVI only vs. PVI + α), including pericardial tamponade (6 vs. 0; p = 0.345) and stroke (1 vs. 1; p = 0.400).
CONCLUSIONS: PVI plus extra PV ablation using a pentaspline PFA catheter is associated with a higher incidence of atrial tachycardia recurrences. For persistent AF, a simpler approach of performing only PVI may be more effective.