MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/anae.16035

Медицинская библиотека · Anaesthesia · 2023

Videolaryngoscopy vs. flexible fibrescopy for tracheal intubation in patients with cervical spine immobilisation: a randomised controlled trial.

Choi S, Yoo H K, Shin K W, Kim Y J, Yoon H K, Park H P, Oh H

Рандомизированное исследованиеСтатьяПеревод в очереди

Аннотация

In patients with cervical spine immobilisation, tracheal intubation devices other than a direct laryngoscope are frequently used to facilitate tracheal intubation and avoid related complications. In this randomised controlled trial, we compared videolaryngoscopic and fibrescopic tracheal intubation in patients with a cervical collar. Tracheal intubation was performed using either a videolaryngoscope with a non-channelled Macintosh blade (n = 166) or a flexible fibrescope (n = 164) in patients having elective cervical spine surgery whose neck was immobilised with a cervical collar to simulate a difficult airway. The primary outcome was the first attempt success rate of tracheal intubation. Secondary outcomes were the overall success rate of tracheal intubation; time to tracheal intubation; use of additional airway manoeuvres; and incidence and severity of tracheal intubation-related airway complications. First attempt success rate was higher in the videolaryngoscope group than in the fibrescope group (164/166 (98.8%) vs. 149/164 (90.9%), p = 0.003). Tracheal intubation was successful within three attempts in all patients. Median (IQR [range]) time to tracheal intubation was shorter (50.0 (41.0-72.0 [25.0-170.0]) s vs. 81.0 (65.0-107.0 [24.0-178.0]) s, p < 0.001) and additional airway manoeuvres were less frequent (30/166 (18.1%) vs. 91/164 (55.5%), p < 0.001) in the videolaryngoscope group compared with the fibrescope group. The incidence and severity of intubation-related airway complications were not different between the two groups. When performing tracheal intubation in patients with a cervical collar, videolaryngoscopy with a non-channelled Macintosh blade was superior to flexible fibrescopy.

Для цитирования: Choi S, Yoo H K, Shin K W, Kim Y J, Yoon H K, Park H P, Oh H. Videolaryngoscopy vs. flexible fibrescopy for tracheal intubation in patients with cervical spine immobilisation: a randomised controlled trial.. Anaesthesia. 2023. DOI: 10.1111/anae.16035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.