MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chemosphere.2024.142534

Медицинская библиотека · Chemosphere · 2024

Non-targeted identification of tianeptine photodegradation products in water samples by UHPLC-QTOF MS/MS.

Cruz Muñoz Enmanuel, Termopoli Veronica, Orlandi Marco, Gosetti Fabio

СтатьяПеревод в очереди

Аннотация

This study aims the characterization of several tianeptine transformation products in ultrapure water by simulated sunlight irradiation. Tianeptine was completely degraded after 106 h of exposition following pseudo-first-order kinetics (half-life time = 12.0 ± 2.4 h). Furthermore, an ultra-high-performance liquid chromatography coupled with a high-resolution quadrupole time-of-flight-mass spectrometry method was developed and fully validated taking into account different method performance parameters for the quantification of tianeptine in river water up to a concentration of 400 pg L-1. Following a non-targeted approach based on mass data-independent acquisition, eight different transformation products not previously reported in the literature were identified and accordingly elucidated, proposing a photodegradation mechanism based on the accurate tandem mass spectrometry information acquired. Irradiation experiments were replicated for a tianeptine solution prepared in a blank river water sample, resulting in the formation of the same transformation products and similar degradation kinetics. In addition, a toxicity assessment of the photoproducts was performed by in silico method, being generally all TPs of comparable toxicity to the precursor except for TP1, and showing a similar persistence in the environment except for TP2 and TP6, while TP4 was the only TP predicted as mutagenic. The developed method was applied for the analysis of four river water samples.

Для цитирования: Cruz Muñoz Enmanuel, Termopoli Veronica, Orlandi Marco, Gosetti Fabio. Non-targeted identification of tianeptine photodegradation products in water samples by UHPLC-QTOF MS/MS.. Chemosphere. 2024. DOI: 10.1016/j.chemosphere.2024.142534.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.