Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC · 2021
Comparison of the Accuracy of INTERGROWTH-21 and Hadlock Ultrasound Formulae for Fetal Weight Prediction.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Marien Mélissa, Perron Sophie, Bergeron Anne-Marie, Singbo Narcisse, Demers Suzanne
Аннотация
OBJECTIVE: To compare the accuracy of INTERGROWTH-21 (IG-21) versus Hadlock1 formulae for birth weight prediction on third-trimester ultrasound in a North American population.
METHODS: This single-centre retrospective cohort study included all pregnant patients who had a third-trimester ultrasound between 340 and 366 weeks gestation and delivered a term singleton at our maternal-fetal medicine reference centre between April 1 and July 30, 2019. Estimated ultrasound fetal weight was calculated with both Hadlock1 and IG-21 formulae for each fetus, then reported on a centile curve to adjust for gestational age at delivery, and compared with the actual birth weight.
RESULTS: The cohort included 600 women. The IG-21 formula had a comparable accuracy to Hadlock1 with mean absolute percentage errors (MAPEs) of 8.64 and 8.86, respectively (P = 0.191). Success rate, defined by a <10% discrepancy range of the actual birth weight, was significantly higher for IG-21 than for Hadlock1 (67.5% vs. 64.3%; P = 0.044).
CONCLUSION: Our results do not support the superiority of IG-21 to Hadlock1. There is a need for continued research to improve birth weight prediction with the ultimate objective of increasing the detection of small for gestation age and macrosomic fetuses.
METHODS: This single-centre retrospective cohort study included all pregnant patients who had a third-trimester ultrasound between 340 and 366 weeks gestation and delivered a term singleton at our maternal-fetal medicine reference centre between April 1 and July 30, 2019. Estimated ultrasound fetal weight was calculated with both Hadlock1 and IG-21 formulae for each fetus, then reported on a centile curve to adjust for gestational age at delivery, and compared with the actual birth weight.
RESULTS: The cohort included 600 women. The IG-21 formula had a comparable accuracy to Hadlock1 with mean absolute percentage errors (MAPEs) of 8.64 and 8.86, respectively (P = 0.191). Success rate, defined by a <10% discrepancy range of the actual birth weight, was significantly higher for IG-21 than for Hadlock1 (67.5% vs. 64.3%; P = 0.044).
CONCLUSION: Our results do not support the superiority of IG-21 to Hadlock1. There is a need for continued research to improve birth weight prediction with the ultimate objective of increasing the detection of small for gestation age and macrosomic fetuses.