Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study.
Аннотация
AIM: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.
SETTINGS AND
DESIGN
The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.
MATERIALS AND
METHODS
Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone. The dies were divided into two groups: Group-A (PEEK) copings and Group-B (zirconia) copings. All copings were fabricated using a CAD/CAM system. Vertical marginal accuracy was assessed with a stereomicroscope and image analysis software at ×20 magnification. The marginal gaP values were subjected to a student (independent) t-test for statistical analysis.
STATISTICAL ANALYSIS USED: The statistical analysis involved a student (independent) t-test to compare the marginal gaP values between Group A (PEEK) and Group B (zirconia).
RESULTS
The mean marginal discrepancy for Group A (PEEK) and Group B (zirconia) was 92.84 μm ± 3.48 μm and 63.12 μm ± 31.47 μm, respectively. A statistically significant variation (t = 3.635, P = 0.001) between the groups was observed, indicating better marginal accuracy with zirconia copings compared to PEEK copings.
CONCLUSION
Both PEEK and zirconia copings demonstrated vertical marginal discrepancies within the clinically acceptable limit of <120 μm. However, zirconia copings exhibited superior marginal accuracy in this in vitro study.