Middle East journal of anaesthesiology · 2005

The intubating laryngeal mask airway Fastrach for emergence after carotid endarterectomy.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Voyagis G S, Dimitriou V, Brimacombe J

Аннотация

We determine the feasibility of using the intubating laryngeal mask airway Fastrach (ILM) as a ventilatory device during emergence from anesthesia after use as an airway intubator in patients undergoing carotid endarterectomy. Thirty-five patients (ASA 2-3, 53-84 yr) were studied. Induction was with midazolam/fentanyl/etomidate and maintenance was with sevoflurane 1-2% in O2 33-50% and N2O. Neuromuscular blockade was with cisatracurium. Tracheal intubation was with a flexible lightwand via the ILM. After successful intubation, the ILM remained in the pharynx, but with the cuff deflated. After surgery, but before anesthesia was discontinued, baseline cardiovascular variables were recorded. The ILM cuff was then reinflated, the tracheal tube removed, the anesthesia breathing system connected to the ILM and anesthesia discontinued. Any changes in the cardiovascular variables greater than +/- 20% baseline values were noted from cuff reinflation to 1 minute after ILM removal. Any adverse respiratory (laryngospasm, coughing, gagging, stridor, SpO2 <94%, end-tidal carbon dioxide >45 mmHg, regurgitation/aspiration) or electrocardiographic (ST segment or rhythm changes) events were also noted. Patients were questioned about postoperative sore throat at 2 and 24 hr. ILM insertion and intubation through the ILM were successful in all patients. Adequate ventilation was achieved in all patients before intubation and after extubation. The mean (range) time taken from cuff reinflation to ILM removal was 9 (5-21) min. The rate pressure product remained within +/- 20% baseline values in all patients. There were no adverse respiratory or electrocardiographic events. There were no adverse neurological events. The surgical field was satisfactory. Postoperative sore throat occurred in 14% at 2 hr and 0% at 24 hr. We conclude that the ILM can be used as a ventilatory device for emergence from anesthesia after use as an airway intubator for carotid endarterectomy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты