High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation.

Linhart Markus, Werner Jessica T, Stöckigt Florian, Kohlmann Annika T, Lodde Pia C, Linneborn Lutz P T, Beiert Thomas, Hammerstingl Christoph, Borràs Roger, Nickenig Georg, Andrié René P, Schrickel Jan W

СтатьяПеревод в очереди

Аннотация

PURPOSE: Congenital atrial septal defect (ASD) is associated with increased morbidity, whereas little is known about the rate of spontaneous closure, associated clinical and echocardiographic parameters, or complications of iatrogenic atrial septal defect (iASD) beyond 1 year of follow-up. Persistent iASD after transseptal puncture for PVI has been described in up to 38% of small cohorts of patients in short-term follow-up after transseptal puncture. We sought to investigate the course of iASD after single transseptal puncture for first pulmonary vein isolation (PVI) with cryoballoon, along with possible risk factors for persistent iASD.

METHODS

After a first PVI with cryoballoon, 102 patients (64 ± 10 years, 64% male) underwent long-term clinical follow-up and comprehensive transthoracic and transesophageal echocardiographic study.

RESULTS

Prevalence of iASD after PVI was 37% after 2.9 (1.6-4.9) years. No clinical complications or deterioration of echocardiographic parameters were associated with iASD. Lower left atrial appendage flow velocity was associated with higher risk of persistence of iASD (3.5% for every 1 cm/s decrease, p = 0.002).

CONCLUSIONS

Despite a high rate of iASD after cryoballoon PVI in long-term follow-up, this was not associated with increased clinical complications. Lower LAA velocity was associated with higher risk of persistent iASD. Repeated routine echocardiographic follow-up may not be necessary in these patients.

Для цитирования: Linhart Markus, Werner Jessica T, Stöckigt Florian, Kohlmann Annika T, Lodde Pia C, Linneborn Lutz P T, Beiert Thomas, Hammerstingl Christoph, Borràs Roger, Nickenig Georg, Andrié René P, Schrickel Jan W. High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2018. DOI: 10.1007/s10840-018-0352-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.