MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.119093

Медицинская библиотека · Biosensors & bioelectronics · 2026

Redox-mediated optochemical plasmonic sensing of H2O2-equivalent reducing capacity in exhaled breath condensate.

Jiang Xiaotong, Gu Wei, Huang Pengxin, Wang Danhua, He Fei, Liang Yirou, Xi Bangchao, Liu Linlin, Li Yunbo, Wu Jiayun, Zha Yang, Qiu Guangyu

СтатьяПеревод в очереди

Аннотация

Oxidative-stress-related diseases generate elevated levels of hydrogen peroxide (H2O2) and other redox-active species in exhaled breath condensate (EBC), offering a promising avenue for non-invasive disease assessment. Despite its diagnostic potential, clinical translation of EBC redox species detection has been constrained by bulky analyzers, labor-intensive operation, and limited sensitivity. By harnessing the redox potential, we present a Redox-mediated Optochemical Plasmonic Sensing (ROPS) system, an ultrasensitive platform that enables real-time, easy-to-use, point-of-care quantitative analysis of H2O2-equivalent reducing capacity in EBC. By coupling H2O2-triggered gold nanoparticle growth on a phase-modulated plasmonic sensor, the ROPS system based on the phase-modulated interferometry achieved a detection limit of 1.19 pM and a wide dynamic range across 4 orders of magnitude. Moreover, the ROPS system demonstrated excellent reusability, maintaining stable H2O2 sensing performance over 40 reuse cycles. To enable point-of-care applications, we further developed a handheld high-efficiency EBC sampler, which harvested exhaled condensate at 2.49 μL/s and enabled an EBC-ROPS sampling-to-biosensing workflow down to 15 min. Clinical evaluation using EBC samples from lung and esophageal cancer patients and matched controls confirmed reliable quantification of trace H2O2-equivalent Au(III)-reducing capacity in complex EBC matrices, highlighting the potential of the integrated ROPS platform as a practical tool for point-of-care and non-invasive oxidative stress-related disease assessment.

Для цитирования: Jiang Xiaotong, Gu Wei, Huang Pengxin, Wang Danhua, He Fei, Liang Yirou, Xi Bangchao, Liu Linlin, Li Yunbo, Wu Jiayun, Zha Yang, Qiu Guangyu. Redox-mediated optochemical plasmonic sensing of H2O2-equivalent reducing capacity in exhaled breath condensate.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.119093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.