MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2022.06.002

Медицинская библиотека · JACC. Clinical electrophysiology · 2022

Bipolar Electroporation Across the Interventricular Septum: Electrophysiological, Imaging, and Histopathological Characteristics.

van Zyl Martin, Ladas Thomas P, Tri Jason A, Yasin Omar Z, Ladejobi Adetola O, Tan Nicholas Y, Christopoulos Georgios, Schneider Noah, Danitz David J, Uecker Darin, DeSimone Christopher V, Killu Ammar M, Maor Elad, Asirvatham Samuel J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Pulsed electric field (PEF) ablation is an emerging modality for the treatment of cardiac arrhythmias. Data regarding effects on the interventricular septum are limited, and the optimal delivery protocol and electrode configuration remain undefined.

OBJECTIVES

This study sought to evaluate the electrophysiological, imaging, and histological characteristics of bipolar direct-current PEF delivered across the interventricular septum.

METHODS

PEF was applied between identical solid-tip ablation catheters positioned on either side of the septum in a chronic canine model. Intracardiac and surface electrophysiological data were recorded following delivery. In 4 animals, cardiac magnetic resonance (CMR) was performed early (6 ± 2 days) and late (30 ± 2 days) postablation. After 4 weeks of survival, cardiac specimens were sectioned for histopathological analysis.

RESULTS

In 8 canines, PEF was delivered in 27 separate septal sites (45 ± 17 J/site) with either microsecond or nanosecond PEF. Acute complications included transient complete atrioventricular block in 5 animals (63%) after delivery at the anterobasal septum, with right bundle branch block persisting in 3 (38%). Ventricular fibrillation occurred in 1 animal during microsecond but not nanosecond PEF. Postprocedural CMR showed prominent edema and significant left ventricular systolic dysfunction, which recovered with late imaging. At 4 weeks, 36 individual well-demarcated lesions were demonstrated by CMR and histopathology. Lesion depth measured by histology was 2.6 ± 2.1 mm (maximum 10.9 mm and near transmural).

CONCLUSIONS

Bipolar PEF ablation of the interventricular septum is feasible and can produce near transmural lesions. Myocardial stunning, edema, and conduction system injury may occur transiently. Further studies are required to optimize safe delivery and efficacious lesions.

Для цитирования: van Zyl Martin, Ladas Thomas P, Tri Jason A, Yasin Omar Z, Ladejobi Adetola O, Tan Nicholas Y, Christopoulos Georgios, Schneider Noah, Danitz David J, Uecker Darin, DeSimone Christopher V, Killu Ammar M, Maor Elad, Asirvatham Samuel J. Bipolar Electroporation Across the Interventricular Septum: Electrophysiological, Imaging, and Histopathological Characteristics.. JACC. Clinical electrophysiology. 2022. DOI: 10.1016/j.jacep.2022.06.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.