Refined Surgical Protocol for the Insertion of Bioactive-coated Titanium Microscrews in the Rat Tibia.

Vera-Becerra Alexis, Valdivia-Gandur Iván, Acuña-Mardones Pablo, Acevedo Francisca, Veuthey Carlos, Beltrán Víctor

СтатьяПеревод в очереди

Аннотация

BACKGROUND/AIM: Sensitive bioactive coatings, such as polycaprolactone with cholecalciferol, present handling challenges in animal models due to their susceptibility to mechanical damage. This study aimed to develop and validate a refined surgical protocol for inserting such polycaprolactone-cholecalciferol-coated titanium microscrews into the proximal tibia of Sprague-Dawley rats, ensuring primary stability and preserving the integrity of the nanofibrous coating.

MATERIALS AND

METHODS

Fourteen male Sprague-Dawley rats (300-350 g) were used: one pilot and 13 animals in the main trial. A 3D anatomical tibia model was created for in-vitro validation of the surgical technique. The refined protocol incorporated enlarged cortical drilling (1.8 mm) before inserting microscrews (1.5×7 mm) to minimize friction on the outer cortical bone. Multimodal anesthesia, postoperative analgesia, and systematic clinical monitoring were implemented. Coating integrity, primary stability, wound healing, and animal welfare were evaluated through clinical observation, micro-computed tomography, and scanning electron microscopy (SEM).

RESULTS

The refined protocol achieved 100% procedural success. All implants reached immediate primary stability with uneventful first-intention healing and no critical adverse events. SEM confirmed preservation of morphology of the nanofibrous coating exclusively in the refined protocol group. Micro-computed tomography demonstrated consistent bone-to-implant contact in both cortical and trabecular compartments. Clinical recovery was rapid and spontaneous, with all animals maintaining optimal welfare indicators throughout follow-up.

CONCLUSION

The refined protocol safeguards the structural integrity of functionalized surfaces, ensures primary stability, and promotes early osseointegration, while complying with the principles of replacement, reduction, and refinement (3Rs). This model provides a valid experimental platform for investigations into osseointegration dynamics and the controlled local release of therapeutic agents.

Для цитирования: Vera-Becerra Alexis, Valdivia-Gandur Iván, Acuña-Mardones Pablo, Acevedo Francisca, Veuthey Carlos, Beltrán Víctor. Refined Surgical Protocol for the Insertion of Bioactive-coated Titanium Microscrews in the Rat Tibia.. In vivo (Athens, Greece). 2026. DOI: 10.21873/invivo.14181.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.