MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.5b02660

Медицинская библиотека · Analytical chemistry · 2015

Quantum dots based potential-resolution dual-targets electrochemiluminescent immunosensor for subtype of tumor marker and its serological evaluation.

Liu Xuan, Jiang Hui, Fang Yuan, Zhao Wei, Wang Nianyue, Zang Guizhen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The identification of subtypes of known tumor markers is of great importance for clinical diagnosis but still a great challenge in novel detection methodologies with simple operation and acceptable sensitivity. This work for the first time reported a quantum dots (QDs) based potential-resolved electrochemiluminescent (ECL) immunosensor to realize simultaneous detection of dual targets. Because of different surface microstructures, dimercaptosuccinic acid stabilized CdTe (DMSA-CdTe) QDs and TiO2 nanoparticles-glutathione stabilized CdTe (TiO2-GSH-CdTe) QDs composites showed a large difference of ECL peak potential (∼360 mV), which provided an access for potential-resolution detection. The ECL emission on indium tin oxide electrodes showed consistent strength during the cyclic scan, and intensity data were collected at -0.89 V and -1.25 V (vs Ag/AgCl) for DMSA-CdTe QDs and TiO2-GSH-CdTe QDs composites, respectively. The interface modification procedures of immunosensor construction were characterized by atomic force microscopy. The portion of Lens culinaris lectin affiliated isoform of alpha fetoprotein (AFP), AFP-L3%, in total AFP, is recently a novel criteria showing even higher sensitivity and specificity than AFP at the early stage of cancer. Combined with the enzyme cyclic amplification strategy, linear ranges for AFP-L3 and AFP dual-targets detection were 3.24 pg mL(-1)-32.4 ng mL(-1) and 1.0 pg mL(-1)-20 ng mL(-1), with limits of detection of 3.24 pg mL(-1) and 1.0 pg mL(-1), respectively. Compared with clinical detection data, the calculated portion of AFP-L3% by as-prepared immunosensor showed acceptable accuracy. These results open a new avenue for facile and rapid multiple-components detection based on the nano-ECL technique and provide a new clinical diagnosis platform for HCC.

Для цитирования: Liu Xuan, Jiang Hui, Fang Yuan, Zhao Wei, Wang Nianyue, Zang Guizhen. Quantum dots based potential-resolution dual-targets electrochemiluminescent immunosensor for subtype of tumor marker and its serological evaluation.. Analytical chemistry. 2015. DOI: 10.1021/acs.analchem.5b02660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.