MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/01.str.0000226904.96059.a6

Медицинская библиотека · Stroke · 2006

In vivo X-ray angiography in the mouse brain using synchrotron radiation.

Kidoguchi Keiji, Tamaki Masahiro, Mizobe Takashi, Koyama Junji, Kondoh Takeshi, Kohmura Eiji, Sakurai Takashi, Yokono Koichi, Umetani Keiji

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: We, for the first time, performed in vivo x-ray angiography in the mouse brain using SPring-8, a third-generation synchrotron radiation facility.

METHODS

A thin PE-50 tube was placed in the unilateral external carotid artery in adult male C57BL/6J mice. While maintaining the blood flow in the internal carotid artery, 33 muL of contrast agent was injected and then selective angiography of the hemisphere was performed.

RESULTS

The average diameters of cerebral artery were as follows: 142.5+/-7.90 microm in middle cerebral artery, 138.3+/-9.35 microm in anterior cerebral artery, 120.5+/-5.53 microm in posterior cerebral artery, and 162.6+/-10.87 microm in internal carotid artery (n=5). To demonstrate the changes in diameter, we induced hypercapnia and detected the dilatation of the vessels between 121% and 124% of the original diameters (n=5). We also repeated angiography in the mice before and after intracarotid injection of vasodilatation drugs papaverine hydrochloride, ATP disodium, and fasudil hydrochloride hydrate and demonstrated the chronological changes in the diameters in each artery at 1, 5, 15, and 30 minutes after injection (n=1 for each drug).

CONCLUSIONS

Using only a minimum volume of the contrast agent, synchrotron radiation enables us to study x-ray angiography in the mouse brain. The morphology of the vessels can be clearly observed under physiological conditions. The diameters and their changes can also be successfully studied in vivo.

Для цитирования: Kidoguchi Keiji, Tamaki Masahiro, Mizobe Takashi, Koyama Junji, Kondoh Takeshi, Kohmura Eiji, Sakurai Takashi, Yokono Koichi, Umetani Keiji. In vivo X-ray angiography in the mouse brain using synchrotron radiation.. Stroke. 2006. DOI: 10.1161/01.str.0000226904.96059.a6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.