Аннотация

OBJECTIVE

The placental cord insertion (PCI) to the placental margin has not been well studied as a continuous variable in relation to birth outcomes. We sought to evaluate the impact of PCI distance on outcomes associated with placental function and development of fetal growth restriction (FGR).

STUDY

DESIGN

This was a retrospective study of singleton gestations that underwent a fetal anatomy ultrasound from 2011-2013. The PCI was recorded as the distance in centimeters from the placental margin. Patients had FGR if the overall estimated fetal weight was <10 % for gestational age or abdominal circumference <5 % in the third trimester. Delivery, obstetric, and neonatal outcomes were obtained via medical chart review. Logistic and linear regression models were used to assess the impact of PCI distance on maternal and neonatal delivery outcomes.

RESULTS

Of the 1443 women who met inclusion criteria, 93.6 % delivered at term. The mean (±SD) PCI distance was 4.4 ± 1.4 cm. There was no association between PCI and cesarean delivery, peripartum hemorrhage (PPH), pre-eclampsia, 5-min Apgar, or intrauterine fetal demise. PCI distance was statistically significantly shorter in patients requiring neonatal intensive care unit (NICU) admission (4.1 ± 1.5 cm vs. 4.4 ± 1.4 cm, p = 0.02) and was associated with lower birthweight (p = 0.01), though this association was no longer seen when corrected for gestational age. There were 3.5 % of patients who developed FGR; PCI distances from the placental edge were not significantly different for patients who developed FGR compared to those who did not (4.2 ± 1.4 cm vs. 4.5 ± 1.4 cm, p = 0.18). Furthermore, a receiver operating characteristic (ROC) curve for PCI had poor sensitivity (area under the curve [AUC] 0.57, 95 % CI 0.49-0.65).

CONCLUSION

PCI distance at the time of fetal anatomic survey is significantly associated with NICU admission, though does not appear to impact rates of preterm birth, pre-eclampsia, PPH or cesarean delivery. PCI distance in singleton gestations does not appear to be predictive of FGR.

Для цитирования: Bigelow Catherine A, Robles Brittany N, Pan Stephanie, Overbey Jessica, Robin Esther, Melamed Alexander, Bianco Angela, Mella Maria Teresa. Placental cord insertion distance from the placental margin and its association with adverse perinatal outcomes.. European journal of obstetrics, gynecology, and reproductive biology. 2020. DOI: 10.1016/j.ejogrb.2020.10.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.