MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2967/jnmt.114.151811

Медицинская библиотека · Journal of nuclear medicine technology · 2015

Tailoring 99mTc-Macroaggregated Albumin Administration to Optimize Patient Dose Reduction.

Gales Sarah L, Peters Sharn K, Salehi Nouria, Better Nathan

СтатьяПеревод в очереди

Аннотация

UNLABELLED: In the ever-changing field of nuclear medicine, best-practice considerations cannot simply go unchallenged for months and years, with the need to minimize radiation exposure to patients highlighted in "as low as reasonably achievable" principles. The Australian Radiation Protection and Nuclear Safety Agency reports that the dose for (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) administered should be 180-200 MBq. An objective of imaging in pulmonary embolism, or indeed any diagnostic procedure involving radiation, is to minimize radiation exposure without sacrificing image quality and diagnostic accuracy. The amount of radiation involved must be considered together with imaging protocols. Our aim was to reduce the amount of (99m)Tc-MAA administered without compromising the diagnostic quality of the scan.

METHODS

To achieve a ventilation-to-perfusion ratio of 1:4, we ventilated the patient as per standard protocol and then placed intravenous access into the patient. For the perfusion component, 180-200 MBq were prepared in a 2-mL injection. Aliquots of 0.5 mL of (99m)Tc-MAA were administered every 30 s followed by a 5-mL saline flush until the required ventilation-to-perfusion ratio was achieved.

RESULTS

With this protocol, the average administered dose was 105 ± 20.7 MBq (vs. 180 ± 5.3 MBq, P < 0.0001).

CONCLUSION

By individually tailoring the administered dose, diagnostic quality is maintained while achieving a significant dose reduction.

Для цитирования: Gales Sarah L, Peters Sharn K, Salehi Nouria, Better Nathan. Tailoring 99mTc-Macroaggregated Albumin Administration to Optimize Patient Dose Reduction.. Journal of nuclear medicine technology. 2015. DOI: 10.2967/jnmt.114.151811.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.