MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/c9an02288k

Медицинская библиотека · The Analyst · 2020

Signal-off electrochemiluminescence immunosensors based on the quenching effect between curcumin-conjugated Au nanoparticles encapsulated in ZIF-8 and CdS-decorated TiO2 nanobelts for insulin detection.

Du Yu, Li Xiaojian, Ren Xiang, Wang Huan, Wu Dan, Ma Hongmin, Fan Dawei, Wei Qin

СтатьяПеревод в очереди

Аннотация

A new strategy for the highly sensitive electrochemiluminescence (ECL) detection of insulin was developed based on curcumin-conjugated Au nanoparticles wrapped in zeolitic Zn2+-imidazolate cross-linked framework nanoparticles (Au-Cur/ZIF-8) quenching the ECL of CdS-decorated TiO2 nanobelts (CdS@TiO2). Curcumin-conjugated Au nanoparticles were embedded in ZIF-8 through epitaxial growth or nucleus coalescence. Herein, dual coreactants H2O2 and K2S2O8 were employed to enhance the ECL emission of CdS@TiO2, and the enhancing mechanism may be due to the electrogenerated hydroxyl radical (OH˙) strengthening the amount of sulfate radical anion (SO4˙-), which was the main species of generating ECL signals. In order to sensitively detect insulin, Au-Cur/ZIF-8 labels were used to anchor secondary antibodies via amidation reaction and inhibit the ECL intensity of CdS@TiO2. Moreover, the possible mechanism of quenching between Au-Cur/ZIF-8 and CdS@TiO2 was ascribed to the poor conductivity of ZIF-8, the consumption of OH˙ and the ECL resonance energy transfer between CdS@TiO2 and Au-Cur. Under optimal conditions, a sandwich immunosensor was prepared to determine insulin with a good linear range from 0.3 pg mL-1 to 20 ng mL-1 and a low detection limit of 0.09 pg mL-1 (S/N = 3).

Для цитирования: Du Yu, Li Xiaojian, Ren Xiang, Wang Huan, Wu Dan, Ma Hongmin, Fan Dawei, Wei Qin. Signal-off electrochemiluminescence immunosensors based on the quenching effect between curcumin-conjugated Au nanoparticles encapsulated in ZIF-8 and CdS-decorated TiO2 nanobelts for insulin detection.. The Analyst. 2020. DOI: 10.1039/c9an02288k.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.