MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.9b02728

Медицинская библиотека · Analytical chemistry · 2019

A Simple 3D-Printed Enzyme Reactor Paper Spray Mass Spectrometry Platform for Detecting BuChE Activity in Human Serum.

Yang Yanmei, Liu Huimin, Chen Zhenzhen, Wu Tianhong, Jiang Zhongyao, Tong Lili, Tang Bo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

To achieve personalized healthcare, a quick, accurate, and high-throughput method to detect disease biomarkers is essential. In the traditional practice, mass spectrometry is one of the most powerful tools and is widely studied. However, the test of human serum usually requires complicated sample pretreatment, tedious operations, and precise condition control, especially for the detection of enzymes as biomarkers. As butyrylcholinesterase (BuChE) has an indicative significance in detecting degenerative disease, liver injury, and organophosphate poisoning, the quick quantification of BuChE is of vital importance to the clinic. In this paper, we report the design and fabrication of a portable 3D-printed enzyme reactor paper spray cartridge (3D ER-PS) with integrated functions: temperature control, enzyme reaction, analyte transfer, and paper spray ionization. Coupled with mass spectrometry, quantitative testing of BuChE activity in human serum was realized conveniently and accurately. While it only requires very simple sample preparation, the results from current 3D ER-PS approach are well consistent with those obtained using Ellman's method. This 3D ER-PS platform not only provides a novel solution for the liquid biopsy of BuChE in clinics but also contributes to the development of quick and targeted medical approaches for analyzing other types of serum biomarker molecules in the field of disease diagnosis.

Для цитирования: Yang Yanmei, Liu Huimin, Chen Zhenzhen, Wu Tianhong, Jiang Zhongyao, Tong Lili, Tang Bo. A Simple 3D-Printed Enzyme Reactor Paper Spray Mass Spectrometry Platform for Detecting BuChE Activity in Human Serum.. Analytical chemistry. 2019. DOI: 10.1021/acs.analchem.9b02728.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.