Reduction in welding fume and metal exposure of stainless steel welders: an example from the WELDOX study.

Lehnert Martin, Weiss Tobias, Pesch Beate, Lotz Anne, Zilch-Schöneweis Sandra, Heinze Evelyn, Van Gelder Rainer, Hahn Jens-Uwe, Brüning Thomas, WELDOX Study Group

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: In a plant where flux-cored arc welding was applied to stainless steel, we investigated changes in airborne and internal metal exposure following improvements of exhaust ventilation and respiratory protection.

METHODS

Twelve welders were examined at a time in 2008 and in 2011 after improving health protection. Seven welders were enrolled in both surveys. Exposure measurement was performed by personal sampling of respirable welding fume inside the welding helmets during one work shift. Urine and blood samples were taken after the shift. Chromium (Cr), nickel (Ni), and manganese (Mn) were determined in air and biological samples.

RESULTS

The geometric mean of respirable particles could be reduced from 4.1 mg/m(3) in 2008-0.5 mg/m(3) in 2011. Exposure to airborne metal compounds was also strongly reduced (Mn: 399 vs. 6.8 μg/m(3); Cr: 187 vs. 6.3 μg/m(3); Ni: 76 vs. 2.8 μg/m(3)), with the most striking reduction inside helmets with purified air supply. Area sampling revealed several concentrations above established or proposed exposure limits. Urinary metal concentrations were also reduced, but to a lesser extent (Cr: 14.8 vs. 4.5 μg/L; Ni: 7.9 vs. 3.1 μg/L). Although biologically regulated, the mean Mn concentration in blood declined from 12.8 to 8.9 μg/L.

CONCLUSION

This intervention study demonstrated a distinct reduction in the exposure of welders using improved exhaust ventilation and welding helmets with purified air supply in the daily routine. Data from area sampling and biomonitoring indicated that the area background level may add considerably to the internal exposure.

Для цитирования: Lehnert Martin, Weiss Tobias, Pesch Beate, Lotz Anne, Zilch-Schöneweis Sandra, Heinze Evelyn, Van Gelder Rainer, Hahn Jens-Uwe, Brüning Thomas, WELDOX Study Group. Reduction in welding fume and metal exposure of stainless steel welders: an example from the WELDOX study.. International archives of occupational and environmental health. 2013. DOI: 10.1007/s00420-013-0884-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.