MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.8b00926

Медицинская библиотека · ACS sensors · 2018

Electrochemical Aptasensor Based on Sulfur-Nitrogen Codoped Ordered Mesoporous Carbon and Thymine-Hg2+-Thymine Mismatch Structure for Hg2+ Detection.

Lai Cui, Liu Shiyu, Zhang Chen, Zeng Guangming, Huang Danlian, Qin Lei, Liu Xigui, Yi Huan, Wang Rongzhong, Huang Fanglong, Li Bisheng, Hu Tianyu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A renewable electrochemical aptasensor was proposed for super-sensitive determination of Hg2+. The novel aptasensor, based on sulfur-nitrogen codoped ordered mesoporous carbon (SN-OMC) and thymine-Hg2+-thymine (T-Hg2+-T) mismatch structure, used ferrocene as signal molecules to achieve the conversion of current signals. In the absence of Hg2+, the thiol-modified T-rich probe 1 spontaneously formed a hairpin structure by base pairing. After being hybridized with the ferrocene-labeled probe 2 in the presence of Hg2+, the hairpin structure of probe 1 was opened due to the preferential formation of the T-Hg2+-T mismatch structure, and the ferrocene signal molecules approached the modified electrode surface. SN-OMC with high specific surface area and ample active sites acted as a signal amplification element in electrochemical sensing. The sensitive determination of Hg2+ can be actualized by analyzing the relationship between the change of oxidation current caused by ferrocene signal molecules and the Hg2+ concentrations. The aptasensor had a fine linear correlation in the range of 0.001-1000 nM with a detection limit of 0.45 pM. The aptasensor also displayed a good response in real sample detection and provided a promising possibility for in situ detection.

Для цитирования: Lai Cui, Liu Shiyu, Zhang Chen, Zeng Guangming, Huang Danlian, Qin Lei, Liu Xigui, Yi Huan, Wang Rongzhong, Huang Fanglong, Li Bisheng, Hu Tianyu. Electrochemical Aptasensor Based on Sulfur-Nitrogen Codoped Ordered Mesoporous Carbon and Thymine-Hg2+-Thymine Mismatch Structure for Hg2+ Detection.. ACS sensors. 2018. DOI: 10.1021/acssensors.8b00926.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.