MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pts.0b013e3181efe30a

Медицинская библиотека · Journal of patient safety · 2010

Performance of a fail-safe system to follow up abnormal mammograms in primary care.

Grossman Ellie, Phillips Russell S, Weingart Saul N

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Missed and delayed breast cancer diagnoses are major sources of potential harm to patients and medical malpractice liability in the United States. Follow-up of abnormal mammogram results is an essential but challenging component of safe breast care. To explore the value of an inexpensive method to follow up abnormal test results, we examined a paper-based fail-safe system.

METHODS

We examined a fail-safe system used to follow up abnormal mammograms at a primary care practice at an urban teaching hospital. We analyzed all abnormal mammogram reports and clinicians' responses to follow-up reminders. We characterized potential lapses identified in this system and used regression models to identify patient, provider, and test result characteristics associated with such lapses.

RESULTS

Clinicians responded to fail-safe reminders for 92% of 948 abnormal mammograms. Clinicians reported that they were unaware of the abnormal result in 8% of cases and that there was no follow-up plan in place for 3% of cases. Clinicians with more years of experience were more likely to be aware of the abnormal result (odds of being unaware per incremental year in practice, 0.92; 95% confidence interval, 0.88-0.97) and were more likely to have a follow-up plan.

CONCLUSIONS

A paper-based fail-safe system for abnormal mammograms is feasible in a primary care practice. However, special care is warranted to ensure full clinician adherence and address staff transitions and trainee-related issues.

Для цитирования: Grossman Ellie, Phillips Russell S, Weingart Saul N. Performance of a fail-safe system to follow up abnormal mammograms in primary care.. Journal of patient safety. 2010. DOI: 10.1097/pts.0b013e3181efe30a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.