MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2023.04.007

Медицинская библиотека · World neurosurgery · 2023

Use of the Globus ExcelsiusGPS System for Robotic Stereoelectroencephalography: An Initial Experience.

Dedrickson Tara, Davidar A Daniel, Azad Tej D, Theodore Nicholas, Anderson William S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Stereoelectroencephalography (SEEG) is a critical tool used in the identification of epileptogenic zones. Although stereotactic frame-based SEEG procedures have been performed traditionally, newer robotic-assisted SEEG procedures have become increasingly common. In this study, we evaluate the accuracy, efficacy of the ExcelsiusGPS robot (Globus Medica, Audubon, PA) in SEEG procedures.

METHODS

Five consecutive adult patients with drug resistant epilepsy were identified as SEEG candidates via a multidisciplinary epilepsy surgery committee. Preoperative scans were merged onto the robot to plan electrode placement. With the use of a camera system, dynamic reference base, and surveillance markers, the robotic arm was used to establish the trajectory of the electrodes. Postoperative computed tomography (CT) scans were merged onto the preoperatively planned trajectory and the radial, depth, and entry errors were calculated. Fiducial registration error was calculated for 4 cases to determine error between the patient and intraoperative CT merge.

RESULTS

A total of 59 electrodes were placed. The mean age at surgery was 41.6 ± 15.1 years. Mean operating room time, anesthesia time, and surgical time was 301.6 ± 44.4 min, 261.6 ± 50.2 min, and 155.8 ± 48.8 min, respectively. The overall mean depth, radial, and entry errors were 2.5 ± 1.9 mm, 1.9 ± 1.5 mm, and 1.6 ± 1.2 mm. Mean fiducial registration error retrospectively calculated for 4 of 5 cases was 0.13 ± 0.04 mm. There were no perioperative complications.

CONCLUSIONS

The initial performance of the ExcelsiusGPS robotic system yielded comparable results to other systems currently in use for adult SEEG procedures.

Для цитирования: Dedrickson Tara, Davidar A Daniel, Azad Tej D, Theodore Nicholas, Anderson William S. Use of the Globus ExcelsiusGPS System for Robotic Stereoelectroencephalography: An Initial Experience.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.