MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.118.009728

Медицинская библиотека · Journal of the American Heart Association · 2018

Pilot Study to Compare the Use of End-Tidal Carbon Dioxide-Guided and Diastolic Blood Pressure-Guided Chest Compression Delivery in a Swine Model of Neonatal Asphyxial Cardiac Arrest.

O'Brien Caitlin E, Reyes Michael, Santos Polan T, Heitmiller Sophia E, Kulikowicz Ewa, Kudchadkar Sapna R, Lee Jennifer K, Hunt Elizabeth A, Koehler Raymond C, Shaffner Donald H

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Background The American Heart Association recommends use of physiologic feedback when available to optimize chest compression delivery. We compared hemodynamic parameters during cardiopulmonary resuscitation in which either end-tidal carbon dioxide ( ETCO 2) or diastolic blood pressure ( DBP ) levels were used to guide chest compression delivery after asphyxial cardiac arrest. Methods and Results One- to 2-week-old swine underwent a 17-minute asphyxial-fibrillatory cardiac arrest followed by alternating 2-minute periods of ETCO 2-guided and DBP -guided chest compressions during 10 minutes of basic life support and 10 minutes of advanced life support. Ten animals underwent resuscitation. We found significant changes to ETCO 2 and DBP levels within 30 s of switching chest compression delivery methods. The overall mean ETCO 2 level was greater during ETCO 2-guided cardiopulmonary resuscitation (26.4±5.6 versus 22.5±5.2 mm Hg; P=0.003), whereas the overall mean DBP was greater during DBP -guided cardiopulmonary resuscitation (13.9±2.3 versus 9.4±2.6 mm Hg; P=0.003). ETCO 2-guided chest compressions resulted in a faster compression rate (149±3 versus 120±5 compressions/min; P=0.0001) and a higher intracranial pressure (21.7±2.3 versus 16.0±1.1 mm Hg; P=0.002). DBP -guided chest compressions were associated with a higher myocardial perfusion pressure (6.0±2.8 versus 2.4±3.2; P=0.02) and cerebral perfusion pressure (9.0±3.0 versus 5.5±4.3; P=0.047). Conclusions Using the ETCO 2 or DBP level to optimize chest compression delivery results in physiologic changes that are method-specific and occur within 30 s. Additional studies are needed to develop protocols for the use of these potentially conflicting physiologic targets to improve outcomes of prolonged cardiopulmonary resuscitation.

Для цитирования: O'Brien Caitlin E, Reyes Michael, Santos Polan T, Heitmiller Sophia E, Kulikowicz Ewa, Kudchadkar Sapna R, Lee Jennifer K, Hunt Elizabeth A, Koehler Raymond C, Shaffner Donald H. Pilot Study to Compare the Use of End-Tidal Carbon Dioxide-Guided and Diastolic Blood Pressure-Guided Chest Compression Delivery in a Swine Model of Neonatal Asphyxial Cardiac Arrest.. Journal of the American Heart Association. 2018. DOI: 10.1161/jaha.118.009728.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.