m+Medelevator.RU
← Поиск публикаций
Academic radiology · 2025

Radiomics-Based Differentiation of Primary Central Nervous System Lymphoma and Solitary Brain Metastasis Using Contrast-Enhanced T1-Weighted Imaging: A Retrospective Machine Learning Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xia Xueming, Qiu Jiajun, Tan Qiaoyue, Du Wei, Gou Qiheng

Аннотация

PURPOSE: To develop and evaluate radiomics-based models using contrast-enhanced T1-weighted imaging (CE-T1WI) for the non-invasive differentiation of primary central nervous system lymphoma (PCNSL) and solitary brain metastasis (SBM), aiming to improve diagnostic accuracy and support clinical decision-making.

METHODS: This retrospective study included a cohort of 324 patients pathologically diagnosed with PCNSL (n=115) or SBM (n=209) between January 2014 and December 2024. Tumor regions were manually segmented on CE-T1WI, and a comprehensive set of 1561 radiomic features was extracted. To identify the most important features, a two-step approach for feature selection was utilized, which involved the use of least absolute shrinkage and selection operator (LASSO) regression. Multiple machine learning classifiers were trained and validated to assess diagnostic performance. Model performance was evaluated using area under the curve (AUC), accuracy, sensitivity, and specificity. The effectiveness of the radiomics-based models was further assessed using decision curve analysis, which incorporated a risk threshold of 0.5 to balance both false positives and false negatives.

RESULTS: 23 features were identified through LASSO regression. All classifiers demonstrated robust performance in terms of area under the curve (AUC) and accuracy, with 15 out of 20 classifiers achieving AUC values exceeding 0.9. In the 10-fold cross-validation, the artificial neural network (ANN) classifier achieved the highest AUC of 0.9305, followed by the support vector machine with polynomial kernels (SVMPOLY) classifier at 0.9226. Notably, the independent test revealed that the support vector machine with radial basis function (SVMRBF) classifier performed best, with an AUC of 0.9310 and the highest accuracy of 0.8780. The selected models-SVMRBF, SVMPOLY, ensemble learning with LDA (ELDA), ANN, random forest (RF), and grading boost with random undersampling boosting (GBRUSB)-all showed significant clinical utility, with their standardized net benefits (sNBs) surpassing 0.6. These results underline the potential of the radiomics-based models in reliably distinguishing PCNSL from SBM.

CONCLUSION: The application of radiomic-driven models based on CE-T1WI has demonstrated encouraging potential for accurately distinguishing between PCNSL and SBM. The SVMRBF classifier showed the greatest diagnostic efficacy of all the classifiers tested, indicating its potential clinical utility in differential diagnosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты