Exponential dosing to standardize myocardial perfusion image quality with rubidium-82 PET.

Tavoosi Anahita, Khetarpal Ritika, Wells R Glenn, Beanlands Rob S B, deKemp Robert A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

82Rb PET is commonly performed using the same injected activity in all patients, resulting in lower image quality in larger patients. This study compared 82Rb dosing with exponential vs proportional functions of body weight on the standardization of myocardial perfusion image (MPI) quality.

METHODS

Two sequential cohorts of N = 60 patients were matched by patient weight. Rest and dipyridamole stress 82Rb PET was performed using 0.1 MBq·kg-2 exponential and 9 MBq·kg-1 proportional dosing. MPI scans were compared qualitatively with visual image quality scoring (IQS) and quantitatively using the myocardium-to-blood contrast-to-noise ratio (CNR) and blood background signal-to-noise ratio (SNR) as a function of body weight.

RESULTS

Average (min-max) patient body weight was 81 ± 18 kg (46-137 kg). Proportional dosing resulted in decreasing CNR, SNR, and visual IQS with increasing body weight (P < 0.05). Exponential dosing eliminated the weight-dependent decreases in these image quality metrics that were observed in the proportional dosing group.

CONCLUSION

82Rb PET dosing as an exponential (squared) function of body weight produced consistent stress perfusion image quality over a wide range of patient weights. Dramatically lower doses can be used in lighter patients, with the equivalent population dose shifted toward the heavier patients to standardize diagnostic image quality.

Для цитирования: Tavoosi Anahita, Khetarpal Ritika, Wells R Glenn, Beanlands Rob S B, deKemp Robert A. Exponential dosing to standardize myocardial perfusion image quality with rubidium-82 PET.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2023. DOI: 10.1007/s12350-023-03303-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.