MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbme.2024.3472689

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2025

Four-Dimensional (4D) Ultrasound Shear Wave Elastography Using Sequential Excitation.

Sun Xin, Chang Chi-Feng, Zhang Junhang, Zeng Yushun, Li Bitong, Sun Yizhe, Kang Haochen, Liu Hsiao-Chuan, Zhou Qifa

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE

Current shear wave elastography methods primarily focus on 2D imaging. To explore mechanical properties of biological tissues in 3D, a four-dimensional (4D, x, y, z, t) ultrasound shear wave elastography is required. However, 4D ultrasound shear wave elastography is still challenging due to the limitation of the hardware of standard ultrasound acquisition systems. In this study, we introduce a novel method to achieve 4D shear wave elastography, named sequential-based excitation shear wave elastography (SE-SWE). This method can achieve 4D elastography implemented by a 1024-element 2D array with a standard ultrasound 256-channel system.

METHODS

The SE-SWE method employs sequential excitation to generate shear waves, and utilizes a 2D array, dividing it into four sub-sections, to capture shear waves across multiple planes. This process involves sequentially exciting each sub-section to capture shear waves, followed by compounding the acquired data from these subsections.

RESULTS

The phantom studies showed strong concordance between the shear wave speeds (SWS) measured by SE-SWE and expected values, confirming the accuracy of this method and potential to differentiate tissues by stiffness. In ex vivo chicken breast experiments, SE-SWE effectively distinguished between orientations relative to muscle fibers, highlighting its ability to capture the anisotropic properties of tissues.

CONCLUSION

The SE-SWE method advances shear wave elastography significantly by using a 2D array divided into four subsections and sequential excitation, achieving high-resolution volumetric imaging at 1.6mm resolution.

SIGNIFICANCE: The SE-SWE method offers a straightforward and effective approach for 3D shear volume imaging of tissue biological properties.

Для цитирования: Sun Xin, Chang Chi-Feng, Zhang Junhang, Zeng Yushun, Li Bitong, Sun Yizhe, Kang Haochen, Liu Hsiao-Chuan, Zhou Qifa. Four-Dimensional (4D) Ultrasound Shear Wave Elastography Using Sequential Excitation.. IEEE transactions on bio-medical engineering. 2025. DOI: 10.1109/tbme.2024.3472689.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.