MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cpf.12450

Медицинская библиотека · Clinical physiology and functional imaging · 2017

An extended high-frequency ultrasound protocol for detection of vessel wall inflammation.

Zachrisson H, Svensson C, Dremetsika A, Eriksson P

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to evaluate an extended protocol of the large vessels using high-frequency duplex ultrasound (DUS) for detection of vessel wall inflammation.

METHODS

Fifty-eight patients performed a DUS examination where arteritis could not be excluded. All DUS examinations were performed using ACUSON S2000 TM ultrasound system (Siemens Medical Solutions USA, Inc.). High-frequency linear transducers were used (18L6 MHz, 9L4MHz) or curve linear for the aortic arch (6C2 MHz). Carotid, vertebral, central neck arteries (subclavian, axillary, innominate) arteries, aortic arch and femoral arteries were studied. Circumferential, homogenous wall thickening, with or without a hyperechogenic stripe lining the innermost layer, were regarded as typical signs of arteritis. Intima-media thickness (IMT) was measured in the patients and a normal control group. The latest clinical updated diagnosis was assessed at least 6 months after DUS.

RESULTS

The DUS findings showed normal vessels (n = 14), arteritis and atherosclerosis (n = 13), atherosclerosis (n = 15) and arteritis (n = 16). The latter group had a significant increased IMT in the common femoral artery and the common carotid artery (mean 1·0 ±  SD 0·3 mm versus 0·6 ± 0·2 mm in the normal group (n = 37), P<0·00001, 1·2 ± 0·5 mm versus 0·8 ± 0·2 mm in the normal group (n = 40), P<0·00001). In the groups with sonographic signs implying arteritis (n = 29), 20 patients had a clinical diagnosis of arteritis, whereas eight patients had another main diagnosis such as malignancy/other inflammatory or infectious disease complicated by inflammation of the vessel wall. One patient had multiple diagnoses and was not possible to classify.

CONCLUSION

An extended ultrasound protocol for central neck and leg arteries could be of value for diagnosis of arteritis. In case of atypical vessel wall inflammation, other main diagnoses should be considered.

Для цитирования: Zachrisson H, Svensson C, Dremetsika A, Eriksson P. An extended high-frequency ultrasound protocol for detection of vessel wall inflammation.. Clinical physiology and functional imaging. 2017. DOI: 10.1111/cpf.12450.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.