MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0100-69912014000300008

Медицинская библиотека · Revista do Colegio Brasileiro de Cirurgioes · 2014

Standardization of pulmonary ventilation technique using volume-controlled ventilators in rats with congenital diaphragmatic hernia.

Gallindo Rodrigo Melo, Gonçalves Frances Lilian Lanhellas, Figueira Rebeca Lopes, Simões Ana Leda Bertoncini, Sbragia Lourenço

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH) using a volume-controlled ventilator.

METHODS

Pregnant rats were divided into the following groups: a) control (C); b) exposed to nitrofen with CDH (CDH); and c) exposed to nitrofen without CDH (N-). Fetuses of the three groups were randomly divided into the subgroups ventilated (V) and non-ventilated (N-V). Fetuses were collected on day 21.5 of gestation, weighed and ventilated for 30 minutes using a volume-controlled ventilator. Then the lungs were collected for histological study. We evaluated: body weight (BW), total lung weight (TLW), left lung weight (LLW), ratios TLW / BW and LLW / BW, morphological histology of the airways and causes of failures of ventilation.

RESULTS

BW, TLW, LLW, TLW / BW and LLW / BW were higher in C compared with N- (p <0.05) and CDH (p <0.05), but no differences were found between the subgroups V and N-V (p> 0.05). The morphology of the pulmonary airways showed hypoplasia in groups N- and CDH, with no difference between V and N-V (p <0.05). The C and N- groups could be successfully ventilated using a tidal volume of 75 ìl, but the failure of ventilation in the CDH group decreased only when ventilated with 50 ìl.

CONCLUSION

Volume ventilation is possible in rats with CDH for a short period and does not alter fetal or lung morphology.

Для цитирования: Gallindo Rodrigo Melo, Gonçalves Frances Lilian Lanhellas, Figueira Rebeca Lopes, Simões Ana Leda Bertoncini, Sbragia Lourenço. Standardization of pulmonary ventilation technique using volume-controlled ventilators in rats with congenital diaphragmatic hernia.. Revista do Colegio Brasileiro de Cirurgioes. 2014. DOI: 10.1590/s0100-69912014000300008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.