Sixteen-row multislice computed tomography in infants with double aortic arch.

Cerillo Alfredo Giuseppe, Amoretti Francesca, Moschetti Riccardo, Murzi Bruno, Chiappino Dante

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

The introduction of multislice computed tomography (MSCT) in 1998 has led to a considerable boost of CT angiography. Four-row MSCT has been employed in the diagnostic assessment of vascular rings. Sixteen-row MSCT is expected to further increase the diagnostic power of MSCT. We report three cases of double aortic arch diagnosed by a 16-row MSCT, and discuss the possible advantages of this diagnostic tool.

PATIENTS AND

METHODS

From April 1, 2003, to September 1, 2003, three patients underwent 16-row MSCT at our institution to evaluate the possible presence of a vascular ring. All patients presented with stridor and feeding difficulties. MSCT was performed under bland sedation (chloral hydrate 60 mg/kg). ECG gating and breath hold were not employed. Three-dimensional reconstructions were employed to assess the presence of airway compromise as well as of vascular anomalies.

RESULTS

Scanning time averaged 4 s (3.8-4.5 s). Motion artefacts were not relevant. The CT scan showed the existence of a vascular anomaly as well as of a significant tracheal compression in all cases, and was considered conclusively diagnostic by the cardiac surgeons. All three patients underwent uncomplicated corrective surgery without further investigations.

CONCLUSION

Sixteen-row MSCT with 3D reconstruction allows a precise evaluation of the airway compromise and a detailed assessment of the anatomy of vascular anomalies. The very short scanning time allows to avoid deep sedation and anaesthesia, and to obtain higher image quality and spatial resolution, with a concomitant reduction of the radiation dose.

Для цитирования: Cerillo Alfredo Giuseppe, Amoretti Francesca, Moschetti Riccardo, Murzi Bruno, Chiappino Dante. Sixteen-row multislice computed tomography in infants with double aortic arch.. International journal of cardiology. 2005. DOI: 10.1016/j.ijcard.2003.12.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.