MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/011871529x320825240925073605

Медицинская библиотека · Cardiovascular & hematological disorders drug targets · 2024

Inter-atrial Septum Stenting in Congenital Heart Disease Patient: A Case Series in Indonesia.

Prakoso Radityo, Kurniawati Yovi, Siagian Sisca Natalia, Sembiring Aditya Agita, Sakti Damba Dwisepto Aulia, Mendel Brian, Lelya Olfi, Lilyasari Oktavia

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Inter-atrial septum (IAS) stenting in duct-dependent congenital heart disease patient has shown to be an effective way to maintain inter-atrial blood flow, however it is still considered a high risk procedure and inter-atrial septum stenting remains a low-frequency procedure.

METHOD: A single-center observational cohort study was carried out at the National Cardiovascular Center Harapan Kita (NCCHK) between April 2019 and April 2023. This study included duct-dependent congenital heart disease patients. The extracted data were baseline characteristics, clinical findings, complications, and outcomes of the patients.

RESULT: Eleven patients with duct-dependent physiology were intervened with inter-atrial septum stenting. The patients were 4 females and 7 males with the median age of implantation being 150 days (range 11-703 days) and the median weight being 3.9 (range 2.8-9) kg, with 2 patients weighing less than 3 kg. The average stent diameter was 8.50 (2.03) mm with an average length of 24.45 (7.94) mm. Non-restrictive atrial flow was successfully achieved in 90.90% of the procedures, corresponding to 10 patients.

CONCLUSION

Inter-atrial septum stenting in duct-dependent congenital heart disease patients produces reliable patency with a very good intra-procedural success rate.

Для цитирования: Prakoso Radityo, Kurniawati Yovi, Siagian Sisca Natalia, Sembiring Aditya Agita, Sakti Damba Dwisepto Aulia, Mendel Brian, Lelya Olfi, Lilyasari Oktavia. Inter-atrial Septum Stenting in Congenital Heart Disease Patient: A Case Series in Indonesia.. Cardiovascular & hematological disorders drug targets. 2024. DOI: 10.2174/011871529x320825240925073605.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.